A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Temperature measurement reliability and validity with thermocouple extension leads or changing lead temperature. | LitMetric

Temperature measurement reliability and validity with thermocouple extension leads or changing lead temperature.

J Athl Train

School of Physical Education, Sport, & Exercise Science, Ball State University, Muncie, IN 47306, USA.

Published: June 2011

Context: Thermocouples' leads are often too short, necessitating the use of an extension lead.

Objective: To determine if temperature measures were influenced by extension-lead use or lead temperature changes.

Design: Descriptive laboratory study.

Setting: Laboratory.

Other Participants: Experiment 1: 10 IT-21 thermocouples and 5 extension leads. Experiment 2: 5 IT-21 and PT-6 thermocouples.

Methods: In experiment 1, temperature data were collected on 10 IT-21 thermocouples in a stable water bath with and without extension leads. In experiment 2, temperature data were collected on 5 IT-21 and PT-6 thermocouples in a stable water bath before, during, and after ice-pack application to extension leads.

Results: In experiment 1, extension leads did not influence IT-21 validity (P  =  .45) or reliability (P  =  .10). In experiment 2, postapplication IT-21 temperatures were greater than preapplication and application measures (P < .05).

Conclusions: Extension leads had no influence on temperature measures. Ice application to leads may increase measurement error.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2978016PMC
http://dx.doi.org/10.4085/1062-6050-45.6.642DOI Listing

Publication Analysis

Top Keywords

extension leads
20
lead temperature
8
temperature measures
8
experiment it-21
8
it-21 thermocouples
8
leads experiment
8
it-21 pt-6
8
experiment temperature
8
temperature data
8
data collected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!