Objective: Gated blood-pool single-photon emission computed tomography (GBPS) was compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular (LV) and right ventricular (RV) ejection fractions (EF) and volumes [end-diastolic volume (EDV) or end-systolic volume (ESV)] in a mixed population.

Methods: Thirty patients (70% men; mean age: 61±14 years) referred for various symptoms or heart diseases, predominantly ischemic, were included. GBPS data were analyzed using segmentation software described earlier based on the watershed algorithm. CMR images were acquired for both ventricles at the same time using a steady-state-free precession sequence and short-axis views. No compensation for papillary muscles was used. LVEF and RVEF and volumes were assessed with GBPS and CMR and were compared.

Results: LVEF and volumes were correlated (P<0.001). The difference in LVEF between GBPS and CMR was not significant (P=0.063). The limits of agreement were close for LVEF (-11 to 15%) and wider for LV volumes (-82 to 11 ml for EDV and -52 to 15 ml for ESV), with higher volume values obtained with CMR (mean differences of 36±24 ml for EDV and 19±17 ml for ESV). The RVEF and volumes assessed by GBPS and CMR were correlated (P<0.001). The difference in RVESV between GBPS or CMR was not significant (P=0.136). The limits of agreement were relatively close for all RV parameters (-15 to 8% for EF; -44 to 22 ml for EDV, and -25 to 21 ml for ESV). In 24 patients without valvulopathy or shunt, the difference between LV stroke volume and RV stroke volume was lower with GBPS than with CMR (9±14 ml and 18±13 ml, respectively, with P=0.027).

Conclusion: GBPS is a simple and widely available technique that can assess both LVEF and RVEF, and volumes with slight differences compared with CMR.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0b013e32834155f1DOI Listing

Publication Analysis

Top Keywords

gated blood-pool
8
comparative values
4
values gated
4
blood-pool spect
4
cmr
4
spect cmr
4
cmr ejection
4
ejection fraction
4
fraction volume
4
volume estimation
4

Similar Publications

 Equilibrium radionuclide angiography (ERNA) has long been assumed as the preferred method to assess cardiac volumes as well as left ventricular systolic and diastolic indices. ERNA was used to diagnose subtle changes in cardiac function during chemotherapy or early stages of heart failure. Gated myocardial perfusion SPECT (GMPS) was introduced as a more feasible and versatile alternative to ERNA, but the precision of GMPS to assess systolic and diastolic indices has not yet been fully reviewed.

View Article and Find Full Text PDF

Planar gated blood pool (GBP-P) radionuclide imaging is a valuable non-invasive technique for assessing left ventricular ejection fraction (LVEF). Serial cardiac imaging can be performed to monitor the potential decline in LVEF among patients undergoing cardiotoxic chemotherapy. Consequently, accurate LVEF determination becomes paramount.

View Article and Find Full Text PDF

Quantitation of mitral regurgitation using positron emission tomography.

EJNMMI Res

September 2024

Molecular Imaging and Medical Physics, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.

Background: Cardiac positron emission tomography (PET) offers non-invasive assessment of perfusion and left ventricular (LV) function from a single dynamic scan. However, no prior assessment of mitral regurgitation severity by PET has been presented. Application of indicator dilution techniques and gated image analyses to PET data enables calculation of forward stroke volume and total LV stroke volume.

View Article and Find Full Text PDF

Purpose: The aim of this study was to generate deep learning-based regions of interest (ROIs) from equilibrium radionuclide angiography datasets for left ventricular ejection fraction (LVEF) measurement.

Patients And Methods: Manually drawn ROIs (mROIs) on end-systolic and end-diastolic images were extracted from reports in a Picture Archiving and Communications System. To reduce observer variability, preprocessed ROIs (pROIs) were delineated using a 41% threshold of the maximal pixel counts of the extracted mROIs and were labeled as ground-truth.

View Article and Find Full Text PDF

A predictive model of super response to cardiac resynchronization therapy in short-term period.

J Interv Card Electrophysiol

November 2024

Department of Surgical Arrhythmology and Cardiac Pacing, Cardiology Research Institute, Tomsk National Research Medical Center, Russian Academy of Sciences, Kievskaya Street, 111a, Tomsk, Russian Federation.

Background: The left bundle branch block, nonischemic heart failure (HF) and female gender are the most powerful predictors of a super response to cardiac resynchronization therapy (CRT). It is important to identify super responders who can derive most benefits from CRT. We aimed to establish a predicting model that could be used for prognosis of a super response to CRT in short-term period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!