Aim: To compare the early bacterial colonization and soft tissue health of mucosa adjacent to zirconia (ZrO(2)) and titanium (Ti) abutment surfaces in vivo.
Materials And Methods: Twenty edentulous subjects received two endosseous mandibular implants. The implants were fitted with either a ZrO(2) or a Ti abutment (non-submerged implant placement, within-subject comparison, left-right randomization). Sulcular bacterial sampling and the assessment of probing pocket depth, recession and bleeding on probing were performed at 2 weeks and 3 months post-surgery. Wilcoxon matched-pairs, sign-rank tests were applied to test differences in the counts of seven marker bacteria and the clinical parameters that were associated with the ZrO(2) and Ti abutments, at the two observation time points.
Results: ZrO(2) and Ti abutments harboured similar counts of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, Peptostreptococcus micros, Fusobacterium nucleatum and Treponema denticola at 2 weeks and 3 months. Healthy clinical conditions were seen around both ZrO(2) and Ti abutments at all times, without significant differences in most clinical parameters of peri-implant soft tissue health. Mean probing depths around Ti abutments were slightly deeper than around ZrO(2) abutments after 3 months (2.2 SD 0.8 mm vs. 1.7 SD 0.7 mm, P=0.03).
Conclusions: No difference in health of the soft tissues adjacent to ZrO(2) and Ti abutment surfaces or in early bacterial colonization could be demonstrated, although somewhat shallower probing depths were observed around ZrO(2) abutments after 3 month.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1600-0501.2010.02005.x | DOI Listing |
Int J Nanomedicine
November 2024
Department of Prosthodontics, Institute of Stomatology & Research Center of Dental Esthetics and Biomechanics, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, People's Republic of China.
BMC Oral Health
September 2024
Prosthodontics Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt.
Background: The purpose of this study was to evaluate the effect of using different types of metallic and non-metallic telescopic crown attachment materials on wear resistance and surface tomography changes in implant-retained mandibular overdentures.
Materials And Methods: Completely edentulous mandibular epoxy models were fabricated, in which two implants were placed in the canine region and retained to the implants with three different material combinations used for the construction of telescopic attachments. Thirty-three identical mandibular overdentures were fabricated using the conventional standardized technique.
Dent Mater
November 2024
Department of Restorative Dentistry, University of Illinois at Chicago, College of Dentistry, Chicago, IL, USA; Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, USA; Department of Biomedical Sciences, University of Illinois-School of Medicine at Rockford, Rockford, IL, USA. Electronic address:
Objective: Implant treatment is provided to individuals with normal, idealized masticatory forces and also to patients with parafunctional habits such as grinding, clenching, and bruxing. Dental erosion is a common increasing condition and is reported to affect 32 % of adults, increasing with age. This oral environment is conducive to tribocorrosion and the potential loss of materials from the implant surfaces and interfaces with prosthetic components.
View Article and Find Full Text PDFBiomed Phys Eng Express
February 2024
Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India.
Traumatic dental injuries can occur due to various reasons such as accidents, sports injuries, fights, falls, and others. These injuries can affect the teeth, gums, and surrounding tissues, and can range from minor chips and cracks to severe fractures, dislocations, and avulsions (when the tooth is completely knocked out of the socket). The most common way to address this is by replacing affected teeth with dental implants.
View Article and Find Full Text PDFJ Clin Med
September 2023
Department of Prosthetic Dentistry and Dental Materials Science, Leipzig University, Liebigstr. 10-12, Haus 1, 04103 Leipzig, Germany.
Chipping of implant-supported molar crowns (iSCs) is a frequently reported complication. This study aimed to investigate the in-vitro aging and fracture resistance of iSCs with a CAD/CAM resin composite veneer structure fabricated with the Rapid Layer Technology (RLT) approach. Eight iSCs per group were fabricated by using two different CAD/CAM resin composites (Shofu Block HC: SH; Grandio blocs: GB) for veneer structures, and zirconia (ZrO), polyetheretherketone (PEEK), and cobalt-chromium (CoCr; control) as framework materials.