The aim of this study was to compare the biomechanical properties of degradable magnesium calcium alloy (MgCa0.8) screws and commonly used stainless steel (S316L) screws and to assess the in vivo degradation behavior of MgCa0.8. MgCa0.8 screws (n=48) and S316L screws (n=32) were implanted into both tibiae of 40 adult rabbits for a follow-up of 2, 4, 6 and 8 weeks. This resulted in a testing group of MgCa0.8 (n=12) and S316L (n=8) screws for each follow-up. Uniaxial pull-out tests were carried out in an MTS 858 Mini Bionix at a rate of 0.1 mm s(-1). For degradation analysis of MgCa0.8 in vivo micro-computed tomography (μCT) was performed to determine the volume of metal alloy remaining. Retrieved MgCa0.8 screws were analysed for degradation by determination of weight changes, scanning electron microscopy and energy dispersive X-ray analyses. No significant differences could be noted between the pull-out forces of MgCa0.8 and S316L 2 weeks after surgery (P=0.121). Six weeks after surgery the pull-out force of MgCa0.8 decreased slightly. In contrast, the S316L pull-out force increased with time. Thus, significantly higher pull-out values were detected for S316L from 4 weeks on (P<0.001). The volume and weight of MgCa0.8 gradually reduced. A corrosion layer, mainly composed of oxygen, magnesium, calcium and phosphorus, formed on the implants. Since MgCa0.8 showed good biocompatibility and biomechanical properties, comparable with those of S316L in the first 2-3 weeks of implantation, its application as a biodegradable implant is conceivable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.actbio.2010.10.031 | DOI Listing |
Am J Sports Med
January 2025
Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA.
Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.
Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.
Study Design: Systematic review; Level of evidence, 5.
Arch Orthop Trauma Surg
January 2025
University Hospital Merkur, Zagreb, Croatia.
Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopedics, First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China. Electronic address:
Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.
Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.
Int Orthop
January 2025
MSk Lab, Imperial College London, London, W12 0BZ, UK.
Purpose: Trauma and orthopaedic (T&O) surgery relies on medical implants and materials, often resulting in metalwork wastage (prosthesis, screws, nails, and plates). This places an economic strain on healthcare services and the environment. Our primary outcome is to quantify the implant wastage across the literature, and secondarily investigate the associated costs in this specialty.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.
Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.
Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!