A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design considerations for proteomic reference materials. | LitMetric

Design considerations for proteomic reference materials.

Proteomics

Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899-8392, USA.

Published: December 2010

In order to improve the repeatability, comparability, and accuracy of MS-based proteomic measurements, there has been considerable international effort to develop appropriate reference materials. Although the majority of reference materials are developed to support measurement quality of routine assays, the development of reference materials for a diverse and changing research field such as proteomics represents unique challenges. In order to define common measurement components and common features of typical proteomic samples, the metrology underpinning proteomics must be considered due to the diversity and changing nature of the field. Reference materials can then be designed around common aspects in order to produce reference materials with the broadest applicability. Reference materials are needed to support both qualitative and quantitative proteomic measurements, involving different design considerations. Consensus and validated statistical approaches to describe the confidence in qualitative measurement, such as protein identification, needs to be established. Common sources of measurement bias also need to be considered in proteomic reference material design.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pmic.201000242DOI Listing

Publication Analysis

Top Keywords

reference materials
28
design considerations
8
reference
8
proteomic reference
8
proteomic measurements
8
materials
7
proteomic
5
considerations proteomic
4
materials order
4
order improve
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!