Dual-mode IVUS catheter for intracranial image-guided hyperthermia: feasibility study.

IEEE Trans Ultrason Ferroelectr Freq Control

Department of Biomedical Engineering, Duke University, Durham, NC, USA.

Published: November 2010

In this study, we investigated the feasibility of modifying 3-Fr IVUS catheters in several designs to potentially achieve minimally-invasive, endovascular access for image-guided ultrasound hyperthermia treatment of tumors in the brain. Using a plane wave approximation, target frequencies of 8.7 and 3.5 MHz were considered optimal for heating at depths (tumor sizes) of 1 and 2.5 cm, respectively. First, a 3.5-Fr IVUS catheter with a 0.7-mm diameter transducer (30 MHz nominal frequency) was driven at 8.6 MHz. Second, for a low-frequency design, a 220-μm-thick, 0.35 x 0.35-mm PZT-4 transducer--driven at width-mode resonance of 3.85 MHz--replaced a 40-MHz element in a 3.5-Fr coronary imaging catheter. Third, a 5 x 0.5-mm PZT-4 transducer was evaluated as the largest aperture geometry possible for a flexible 3-Fr IVUS catheter. Beam plots and on-axis heating profiles were simulated for each aperture, and test transducers were fabricated. The electrical impedance, impulse response, frequency response, maximum intensity, and mechanical index were measured to assess performance. For the 5 x 0.5-mm transducer, this testing also included mechanically scanning and reconstructing an image of a 2.5-cm-diameter cyst phantom as a preliminary measure of imaging potential.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018697PMC
http://dx.doi.org/10.1109/TUFFC.2010.1723DOI Listing

Publication Analysis

Top Keywords

ivus catheter
12
3-fr ivus
8
dual-mode ivus
4
catheter
4
catheter intracranial
4
intracranial image-guided
4
image-guided hyperthermia
4
hyperthermia feasibility
4
feasibility study
4
study study
4

Similar Publications

Article Synopsis
  • Heavily calcified coronary artery disease complicates percutaneous coronary intervention (PCI), requiring advanced techniques like cutting balloons (CB), which need standardization for better effectiveness.
  • The study presents the RODIN-CUT technique, which involves sequential CB inflations guided by intravascular ultrasound (IVUS) to improve plaque modification and stent expansion in difficult cases.
  • Results indicate that RODIN-CUT achieved high procedural success rates and minimal complications, suggesting it could be a simple and cost-effective method for treating calcified lesions, though larger studies are needed to confirm its validity.
View Article and Find Full Text PDF

Background: The role of Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) is still unclear in patients with STEMI undergoing PCI in the current second-generation DES era.

Aims: This study aimed to evaluate the trends and outcomes of IVUS-guided PCI in patients with STEMI.

Methods: We used the National Inpatient Sample (NIS) database from 2016 to 2021.

View Article and Find Full Text PDF

Background: Intravascular ultrasound (IVUS)-guided optimization of suboptimal fractional flow reserve (FFR) following percutaneous coronary intervention (PCI) results in a significant increase in both post-PCI FFR and minimal lumen and stent areas (MLA and MSA, respectively). However, the impact of clinical presentation with non-ST-segment elevation acute coronary syndrome (NSTE-ACS) versus chronic coronary syndrome (CCS) on the efficacy of PCI optimization remains unknown.

Methods: This was a prespecified subgroup analysis of the FFR REACT trial comparing IVUS-guided PCI optimization versus no further treatment in 291 patients with a post-PCI FFR < 0.

View Article and Find Full Text PDF

A 48-year-old male with a history of hyperlipidemia presented to the emergency department with chest pain. Electrocardiographic abnormalities indicated an acute coronary syndrome. Urgent coronary angiography revealed nondominant right coronary artery (RCA) occlusion.

View Article and Find Full Text PDF

Intravascular Ultrasound for the Prevention of Coronary Artery Occlusion During Transcatheter Aortic Valve Replacement.

Catheter Cardiovasc Interv

December 2024

Department of Cardiology, University Hospital, Institute of Medical Sciences, University of Opole, Opole, Poland.

Predicting coronary artery occlusion after transcatheter aortic valve replacement (TAVR) is usually based on computed tomography angiography (CTA). The primary risk factors seem to be a low coronary artery take-off and a small aortic root. However, CTA sometimes provides ambiguous risk assessment, and even if a potentially risky coronary artery is secured with a guidewire, the need for coronary stenting after valve implantation often remains uncertain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!