Challenges in relating experimental hip implant fixation predictions to clinical observations.

J Biomech

The Implant Biomechanics Laboratory of the J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Los Angeles Orthopaedic Hospital-UCLA, 2400 South Flower Street, Los Angeles, CA 90007, USA.

Published: January 2011

Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynamic joint reaction force, torque, and muscle force, to assess the relative effects of surface finish and collars on interface fixation. Four each of four otherwise identical straight femoral stems, varying only in surface finish and presence or lack of collars were used. Specimens were tested under two conditions: (1) with intact interfaces simulating immediate post-operative conditions and (2) with a thin-film at the stem-cement interface, simulating conditions several weeks to months post-operative when fibrous tissue has formed with the implant still stable. Micromotion was measured at both interfaces in three directions. Surface finish had a larger relative effect than collars, regardless of whether or not a thin-film was present. For example, a proximal grit-blasted finish enhanced fixation at the stem-cement interface by 7-12 μm per-cycle (p<0.05) and decreased early cement mantle loosening by 7-13 μm. For straight stems, rougher surfaces provided greater stability than polished, even with a thin film at the stem-cement interfaces, contradicting the theory that once debonded, rough stems are less stable than polished at the stem-cement interface. The findings of this experimental study exemplify the need to take advantage of all available tools for the preclinical evaluation of orthopaedic implants, including long-term clinical observations of related devices, analytical and numeric models, and experimental bench-top simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2010.10.006DOI Listing

Publication Analysis

Top Keywords

surface finish
12
femoral components
8
stem-cement interface
8
challenges relating
4
relating experimental
4
experimental hip
4
hip implant
4
implant fixation
4
fixation predictions
4
predictions clinical
4

Similar Publications

Coating Agents for Resin Composites: Effect on Color Stability, Roughness, and Surface Micromorphology Subjected to Brushing Wear.

Oper Dent

January 2025

*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.

This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.

View Article and Find Full Text PDF

It is well known that elite athletes of specific ethnicities and/or nationalities dominate certain sports disciplines (e.g., East Africans in marathon running).

View Article and Find Full Text PDF

Aluminium-lithium (Al-Li) 2060 alloy, a 3rd generation Al-Li alloy, is considered a structural material for aircraft components. This study employs the Friction Stir Welding (FSW) process with a kinematic 5-axis robotic arm to weld 4-mm-thick plates of 2060-T8E30 Al-Li alloy. The focus is on the impact of tool axial force and speeds on the microstructural evolution, mechanical properties, and surface integrity of the welded joints.

View Article and Find Full Text PDF

Background: Conservative dentistry introduced modern restoration designs, contributing to the greater use of partial-coverage ceramic restorations. New strong bondable ceramic materials made fabricating partial coverage ceramic restorations easier to restore the badly destructed teeth.

Aim Of The Study: This study investigated the impact of three distinct overlay preparation designs on the marginal fit (both before and after thermal aging) and the fracture resistance of overlay restorations fabricated using advanced zirconia-reinforced lithium disilicate (ALD) CAD/CAM glass-ceramic blocks.

View Article and Find Full Text PDF

The purpose of this review is to gain attention about intro the advanced and green technology that has dual action for both clean wastewater and produce energy. Water scarcity and the continuous energy crisis have arisen as major worldwide concerns, requiring the creation of ecologically friendly and sustainable energy alternatives. The rapid exhaustion of fossil resources needs the development of alternative energy sources that reduce carbon emissions while maintaining ecological balance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!