Nurse:patient ratio and achievement of oxygen saturation goals in premature infants.

Arch Dis Child Fetal Neonatal Ed

Division of Neonatology, Connecticut Children's Medical Center, 282 Washington Street, Hartford, CT 06106, USA.

Published: March 2011

Background: Premature newborns often experience oxygen saturations outside policy-specified targets, which may be associated with increased morbidity. Nurse workload may affect oxygen management.

Objective: To examine the relationship between number of patients assigned to neonatal intensive care unit (NICU) nurses and achievement of oxygen saturation goals in premature newborns.

Design: The authors linked nurse-patient assignment data with continuous oxygen saturation data for infants <29 weeks' gestation in a single NICU between January and June 2008. The proportion of time oxygen saturation was in policy-specified target range (85-92%) and proportion of time hyperoxaemic (98-100%) were determined for multiple 6 h monitoring periods. Each period was characterised by a single nurse, respiratory support mode and fraction of inspired oxygen (Fio(2)) level (0.22-0.49 or ≥0.5). The nurse:patient ratio for the infant's nurse for each monitoring period was determined. Factors associated with Spo(2) target achievement and hyperoxaemia were identified.

Results: The authors analysed 1019 monitoring periods from 14 infants with a mean (SD) birth weight of 860 (270) g and gestational age of 26.6 (1.6) weeks. The mean (range) postmenstrual age for all monitoring periods was 31.6 (24.1-40.7) weeks. Eighty-seven nurses provided care. In a multivariate cross-classified hierarchical regression, the nurse:patient ratio, postmenstrual age, respiratory support mode and Fio(2) were significantly associated with oxygen saturation outcomes. Fewer patients per nurse was significantly associated with a higher saturation target achievement among patients on high-frequency ventilation, and with reduced hyperoxaemia among patients on nasal cannula.

Conclusions: Fewer patients per nurse may be associated with improved achievement of oxygen saturation goals and may be an important modifiable factor influencing oxygen-related outcomes in premature newborns. This effect may vary with mode of respiratory support.

Download full-text PDF

Source
http://dx.doi.org/10.1136/adc.2009.178616DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
12
achievement oxygen
8
saturation goals
8
goals premature
8
oxygen
5
nursepatient ratio
4
ratio achievement
4
premature infants
4
infants background
4
background premature
4

Similar Publications

Assessing how at-risk species respond to co-occurring stressors is critical for predicting climate change vulnerability. In this study, we characterized how young-of-the-year White Sturgeon () cope with warming and low oxygen (hypoxia) and investigated whether prior exposure to one stressor may improve the tolerance to a subsequent stressor through "cross-tolerance". Fish were acclimated to five temperatures within their natural range (14-22°C) for one month prior to assessment of thermal tolerance (critical thermal maxima, CTmax) and hypoxia tolerance (incipient lethal oxygen saturation, ILOS; tested at 20°C).

View Article and Find Full Text PDF

Objective: Machine learning (ML) may allow for improved discernment of hemodynamics and oxygen delivery compared to standard invasive monitoring. We hypothesized that an ML algorithm could predict impaired delivery of oxygen (IDO) with comparable discrimination to invasive mixed venous oxygen saturation (SvO) measurement.

Methods: A total of 230 patients not on mechanical circulatory support (MCS) managed with a pulmonary artery catheter (PAC) were identified from 1012 patients admitted to a single cardiovascular intensive care unit (CVICU) between April 2021 and January 2022.

View Article and Find Full Text PDF

Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.

View Article and Find Full Text PDF

GLITTRE-ADL TESTS IN THREE LAPS AS AN ALTERNATIVE TO THE FIVE LAPS TEST.

Respir Med

January 2025

Allied Health Professorial Unit, Sydney Local Health District, Sydney, New South Wales, Australia; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales, Australia.

Background: The Glittre-ADL test is a comprehensive test to evaluate functional capacity in patients with chronic obstructive pulmonary disease (COPD).

Aim: The primary aim was to validate the Glittre-ADL test with and without the backpack performed in three laps as an alternative of five laps in people with COPD.

Methods: Forty-eight participants with mild to severe COPD (mean±SD age: 71±7 years; FEV: 46 ± 17 %predicted) were recruited and performed two six-minute walk tests (visit 1); two Glittre-ADL tests with backpack (visit 2), and the Glittre-ADL test with and without the backpack, in random order (visit 3).

View Article and Find Full Text PDF

To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!