AI Article Synopsis

Article Abstract

The light detection and ranging Thomson scattering (TS) diagnostic is advantageous since it only requires a single view port into the tokamak. This technique requires a short pulse laser at high energy, usually showing a limited repetition rate. Having multiple lasers will increase the repetition rate. This paper presents a scanning mirror as a laser beam combiner. Measurements of the position accuracy and jitter show that the pointing stability of the laser beam is within ±25 μrad for over tens of seconds. A control feedback loop is implemented to demonstrate the long term stability. Such a system could be applied for ITER and JET.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3485081DOI Listing

Publication Analysis

Top Keywords

laser beam
12
beam combiner
8
thomson scattering
8
repetition rate
8
laser
4
combiner thomson
4
scattering core
4
core lidar
4
lidar light
4
light detection
4

Similar Publications

Potential for reduction of radiation dose in the assessment of the lead orientation in directional deep brain stimulation electrodes.

Eur J Radiol

January 2025

Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; Fraunhofer Institute for Laser Technology (ILT), 52074 Aachen, Germany.

Purpose: Directional deep brain stimulation (dDBS) relies on electrodes steering the stimulation field in a specific direction. Post implantation, however, the intended and real orientation of the lead frequently deviates e.g.

View Article and Find Full Text PDF

Radiographical impact of photobiomodulation therapy on bone regeneration in clinical studies: a systematic review.

Lasers Med Sci

January 2025

International Network for Photo Medicine and Photo Dynamic Therapy (INPMPDT), Universal Scientific Education and Research Network (USERN), Tehran, Iran.

Bone regeneration is a complex process influenced by inflammation and pathological conditions. Efforts to enhance this process include chemical and physical interventions, with PBMT therapy showing promise in improving bone regeneration. Despite conflicting findings in existing literature, this review aims to synthesize clinical evidence on using therapy (PBMT) in bone regeneration and explore its potential clinical applications.

View Article and Find Full Text PDF

New Numerical Inversion Method to Improve the Spatial Accuracy of Elemental Imaging for LA-ICP-MS.

Anal Chem

January 2025

State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan 430074, PR China.

The elemental imaging of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) provides spatial information on elements and therefore can further investigate the growth or evolution processes of an analyte. However, the accurate determination of spatial information is limited by the decoupling between the elemental distribution and mass spectrometry signals. This phenomenon, which is more distinct when high-diffusion ablation cells are used, arises from the overlap of ablation and the transport dispersion of aerosols.

View Article and Find Full Text PDF

Convergent-beam attosecond x-ray crystallography.

Struct Dyn

January 2025

Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany.

Sub-ångström spatial resolution of electron density coupled with sub-femtosecond to few-femtosecond temporal resolution is required to directly observe the dynamics of the electronic structure of a molecule after photoinitiation or some other ultrafast perturbation, such as by soft X-rays. Meeting this challenge, pushing the field of quantum crystallography to attosecond timescales, would bring insights into how the electronic and nuclear degrees of freedom couple, enable the study of quantum coherences involved in molecular dynamics, and ultimately enable these dynamics to be controlled. Here, we propose to reach this realm by employing convergent-beam x-ray crystallography with high-power attosecond pulses from a hard-x-ray free-electron laser.

View Article and Find Full Text PDF

To measure the influence of ganglion cell layer (GCL) thickness on the changes in size and red blood cell (RBC) flow in small retinal vessels evoked by full-field flicker. We used a dual-beam adaptive optics scanning laser ophthalmoscope to image 11 healthy young controls in two retinal areas with significantly different GCL thicknesses. All capillaries and arterioles of the superficial vascular plexus were responsive to the flicker stimulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!