Unsealed beta-gamma-emitting sources are used (15 GBq (90)Y each session) in nuclear medicine therapeutic procedures. Inside the manipulation cell and while giving the injection to the patient, the skin exposure is very high; electron radiation field is not homogeneous and thus the exposure of the extremities is not uniform. Particular individual monitoring is adopted: single thermoluminescence dosemeter, wrapped in polyethylene film and placed on an adhesive tape, is positioned on the tip of the fingers; 6-10 dosemeters are assigned to each operator per session. The energy and angle response is studied for X-ray spectra, (90)Sr/Y and (204)Tl--a unique mean calibration factor is calculated in order to estimate H(p)(0.07). Performance of dosemeter is analysed according to ISO 62387-1(2007) and the combined uncertainty (calculated using the Monte Carlo method) results lie in the order of 11 %. This method reveals the critical step of manipulation and administration and ensures that dose limits are not exceeded.