A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improvements in patient-reported outcomes and visual acuity after bilateral implantation of multifocal intraocular lenses with +3.0 diopter addition: multicenter clinical trial. | LitMetric

Purpose: To assess changes in patient-reported outcomes, satisfaction, vision quality, and visual acuity after bilateral implantation of multifocal intraocular lenses (IOLs) with a 3.00 D addition (add) in cataract patients.

Setting: Twelve study centers, United States.

Design: Randomized multicenter clinical trial.

Methods: In this 6-month trial, cataract patients had bilateral implantation of the AcrySof IQ ReSTOR +3.0 IOL (model SN6AD1). Patient-reported outcomes were collected using the Cataract TyPE questionnaire. Clinical outcomes included uncorrected near (UNVA), uncorrected intermediate (UIVA), and uncorrected distance (UDVA) visual acuities.

Results: The study comprised 147 patients. From preoperatively to 6 months postoperatively, the mean UDVA improved from 0.45 logMAR (approximate Snellen, 20/56) to 0.04 logMAR (20/22 Snellen), the mean UIVA from 0.56 logMAR (20/73) to 0.17 logMAR (20/30), and the mean UNVA from 0.62 logMAR (20/83) to 0.10 logMAR (20/25); all improvements were clinically and statistically significant (P<.0001). There was also a statistically significant improvement in patient satisfaction with uncorrected vision (P<.0001). Clinically and statistical significant reductions occurred in trouble with vision (daytime and nighttime), trouble with glare, limitations with UDVA, limitations with UNVA, and limitations in social activities (P<.0001).

Conclusions: Bilateral implantation of multifocal intraocular lenses (IOLs) with a 3.00 D add produced statistically significant and clinically relevant postoperative improvements in UNVA, UIVA, and UDVA. Commensurate significant postoperative improvements were observed in the patient-reported uncorrected functional vision, satisfaction with uncorrected vision, and social activities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2010.05.028DOI Listing

Publication Analysis

Top Keywords

patient-reported outcomes
12
bilateral implantation
12
visual acuity
8
acuity bilateral
8
implantation multifocal
8
multifocal intraocular
8
intraocular lenses
8
multicenter clinical
8
logmar
6
improvements patient-reported
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!