A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dimensional alterations and solubility of new endodontic sealers. | LitMetric

This study evaluated the dimensional alterations and the solubility of two experimental endodontic sealers based on Copaifera multijuga oil-resin (Biosealer) and castor oil bean cement (Poliquil), maintained in different storage solutions. Twenty specimens (3 mm diameter and 2 mm height) of each sealer were assigned to 2 groups (n=10) according to the storage solution: simulated tissue fluid (STF) or distilled water (DW). The specimens were stored in these solutions during 90 days, being removed every 30 days for weighting. The solutions were renewed every 15 days. The results were subjected to statistical analysis by Dunn's and Mann-Whitney tests (a=0.05). The solubility of Poliquil was higher in STF (38.4 ± 36.0) than in DW (28.4 ± 15.0), while Biosealer showed higher solubility in DW (34.61 ± 6.0) than in STF (18.59 ± 8.0). The storage solution influenced the behavior of sealers in relation to the weight variation (p=0.0001). Poliquil presented higher variation of weight independent of the solution (p=0.239). Biosealer also presented higher variation of weight regardless of the solution (p=0.0001). The solubility of Biosealer was different from that of Poliquil, but both sealers showed low solubility in STF. Under the tested conditions, neither of the materials were according to the ADA'S specification.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402010000400002DOI Listing

Publication Analysis

Top Keywords

dimensional alterations
8
alterations solubility
8
endodontic sealers
8
storage solution
8
presented higher
8
higher variation
8
variation weight
8
solubility
6
solubility endodontic
4
sealers
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!