Background: Pedicle screw misplacement is relatively common, with reported rates ranging up to 42%. Although computer-assisted image guidance (CaIG) has been shown to improve accuracy in open spinal surgery, its use in minimally invasive procedures has not been as well evaluated. We present our technique and review the results from a cohort of patients who underwent minimally invasive lumbar pedicle screw placement utilizing the O-arm imaging unit in conjunction with the StealthStation Treon System.

Methods: A retrospective review of patients who underwent minimally invasive pedicle screw fixation with CaIG was performed. Eleven consecutive patients were identified and all were included. Nine patients underwent a single-level transforaminal lumbar interbody fusion. Two patients underwent multi-level fusion. Inaccurate pedicle screw placement was determined by postoperative computed tomography (CT) and graded as 0-2, 2-4, 4-6, or 6-8 mm.

Results: A total of 52 screws were placed. Forty screws were inserted in eight patients who had postoperative CT, and a misplacement rate of 7.5% was noted including one lateral and two medial breaches. All breaches were graded as 0-2 mm and were asymptomatic. In the remaining three patients, post-instrumentation O-arm imaging did not demonstrate pedicle screw misplacement.

Conclusion: Although this initial study evaluates a relatively small number of patients, minimally invasive pedicle screw fixation utilizing the O-arm and StealthStation for CaIG appears to be safe and accurate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2958329PMC
http://dx.doi.org/10.4103/2152-7806.68705DOI Listing

Publication Analysis

Top Keywords

pedicle screw
28
minimally invasive
20
patients underwent
16
invasive pedicle
12
screw fixation
12
utilizing o-arm
12
fixation utilizing
8
patients
8
underwent minimally
8
screw placement
8

Similar Publications

Objective: When creating minimally invasive spine fusion constructs, accurate pedicle screw fixation is essential for biomechanical strength and avoiding complications arising from delicate surrounding structures. As research continues to analyze how to improve accuracy, long-term patient outcomes based on screw accuracy remain understudied. The objective of this study was to analyze long-term patient outcomes based on screw accuracy.

View Article and Find Full Text PDF

Introduction: As medical education becomes more complex, the demand for advanced teaching and training methods has grown. Technological advancements have opened up new possibilities, particularly in the realm of virtual reality (VR) simulations for training.

Research Question: Our prospective, randomized pilot study aims to assess whether a novel VR-based 3D training platform can effectively teach the knowledge and skills needed for complex spinal surgery, specifically pedicle screw placement.

View Article and Find Full Text PDF

Purpose: To describe a novel alternative technique for C2 fixation under the concept of atlantoaxial joint distraction and fusion with intra-articular Cages, and to report its preliminary clinical outcomes.

Methods: Eighteen patients with basilar invagination and atlantoaxial dislocation underwent atlantoaxial joint distraction and fusion with intra-articular Cages. All patients had hypoplasia of the C2 isthmus prohibiting insertion of the pedicle screw.

View Article and Find Full Text PDF

Background: Comparative studies of posterior lumbar interbody fusion with cortical bone trajectory and pedicle screw in older patients, particularly in those aged ≥ 80 years, are rare. This study aimed to retrospectively analyze the clinical and surgical outcomes following posterior lumbar interbody fusion with pedicle screw fixation compared to cortical bone trajectory in patients aged ≥ 80 years with degenerative lumbar spine disease.

Methods: We included 68 patients aged ≥ 80 years who underwent degenerative lumbar spinal surgery at our spine center between January 2011 and December 2020.

View Article and Find Full Text PDF

Spine surgery is highly litigious; misplaced screws and intraoperative neuromonitoring frequently feature in lawsuits. Intraoperative neuromonitoring aims to prevent injury but its standards are debated, and literature suggests its benefits are mixed. We surveyed its use among neurosurgeons from the Congress of Neurological Surgeons with Pearson's chi-square test applied to analyse data within R.

View Article and Find Full Text PDF