Perceptual sensitivity to first harmonic amplitude in the voice source.

J Acoust Soc Am

Division of Head and Neck Surgery, School of Medicine, University of California, Los Angeles, 31-24 Rehab Center, Los Angeles, California 90095-1794, USA.

Published: October 2010

Little is known about the perceptual importance of changes in the shape of the source spectrum, although many measures have been proposed and correlations with different vocal qualities (breathiness, roughness, nasality, strain...) have frequently been reported. This study investigated just-noticeable differences in the relative amplitudes of the first two harmonics (H1-H2) for speakers of Mandarin and English. Listeners heard pairs of vowels that differed only in the amplitude of the first harmonic and judged whether or not the voice tokens were identical in voice quality. Across voices and listeners, just-noticeable-differences averaged 3.18 dB. This value is small relative to the range of values across voices, indicating that H1-H2 is a perceptually valid acoustic measure of vocal quality. For both groups of listeners, differences in the amplitude of the first harmonic were easier to detect when the source spectral slope was steeply falling so that F0 dominated the spectrum. Mandarin speakers were significantly more sensitive (by about 1 dB) to differences in first harmonic amplitudes than were English speakers. Two explanations for these results are possible: Mandarin speakers may have learned to hear changes in harmonic amplitudes due to changes in voice quality that are correlated with the tones of Mandarin; or Mandarin speakers' experience with tonal contrasts may increase their sensitivity to small differences in the amplitude of F0 (which is also the first harmonic).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2981120PMC
http://dx.doi.org/10.1121/1.3478784DOI Listing

Publication Analysis

Top Keywords

amplitude harmonic
12
voice quality
8
differences amplitude
8
mandarin speakers
8
harmonic amplitudes
8
harmonic
6
mandarin
5
perceptual sensitivity
4
sensitivity harmonic
4
amplitude
4

Similar Publications

This study delves into the feasibility of leveraging quasi-static component (QSC) generation during primary Lamb wave propagation to discern subtle alterations in the interfacial properties of a two-layered plate. Unlike the second-harmonic generation of Lamb waves, QSC generation doesn't necessitate precise phase-velocity matching but rather requires an approximate matching of group velocities to ensure the emergence of cumulative growth effects. This unique characteristic empowers the QSC-based nonlinear ultrasonic method to effectively surmount the limitations associated with inherent dispersion and multimode traits of Lamb wave propagation.

View Article and Find Full Text PDF

Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.

View Article and Find Full Text PDF

Effect of a Wrist Harmonic Liquid Tremor Absorber-Damping on the Upper Extremity Essential Tremor.

Mov Disord

January 2025

ALEA Neurotechnology Research and Development Company, Ankara, Türkiye.

Background: Essential tremor (ET) is a common type of tremor. Previous research has shown that wearable orthoses and biomechanical loading methods can suppress tremors.

Objective: This study aims to investigate the effect of a harmonic liquid dampener on upper extremity ET.

View Article and Find Full Text PDF

Identifying and understanding the nonlinear behavior of memristive devices.

Sci Rep

December 2024

Chair of Applied Electrodynamics and Plasma Technology, Ruhr University Bochum, Universitätsstraße 150, 44780, Bochum, Germany.

Nonlinearity is a crucial characteristic for implementing hardware security primitives or neuromorphic computing systems. The main feature of all memristive devices is this nonlinear behavior observed in their current-voltage characteristics. To comprehend the nonlinear behavior, we have to understand the coexistence of resistive, capacitive, and inertia (virtual inductive) effects in these devices.

View Article and Find Full Text PDF

Long time series of velocity profiles collected by up-looking acoustic profilers in the westernmost sill of the Strait of Gibraltar show an unexpected pattern in the deepest ∼80 m of the water column, consisting in an appreciable diurnal weakening of the measured horizontal velocity. A harmonic analysis performed on long time series reveals a surprising magnitude of S constituent (exactly 1 cpd of frequency) in the horizontal velocity and echo amplitude, which prevails over the rest of diurnal constituents within this depth range, including K, despite being around 200 times smaller than it in the tide generating potential. High resolution echograms collected by a new instrument recently installed in the mooring line, point at the diel vertical migration of living acoustic scatterers (zooplankton) as the most reasonable cause.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!