A number of effects of weak combined (static and alternating) magnetic fields with an alternating component of tens and hundreds nT at a collinear static field of 42 microT, which is equivalent to the geomagnetic field, have been found: the activation of fission and regeneration of planarians Dugesia tigrina, the inhibition of the growth of the Ehrlich ascites carcinoma in mice, the stimulation of the production of the tumor necrosis factor by macrophages, a decrease in the protection of chromatin against the action of DNase 1, and the enhancement of protein hydrolysis in systems in vivo and in vitro. The frequency and amplitude ranges for the alternating component of weak combined magnetic fields have been determined at which it affects various biological systems. Thus, the optimal amplitude at a frequency of 4.4 Hz is 100 nT (effective value); at a frequency of 16.5 Hz, the range of effective amplitudes is broader, 150-300 nT; and at a frequency of 1 (0.5) Hz, it is 300 nT. The sum of close frequencies (e.g., 16 and 17 Hz) produces a similar biological effect as the product of the modulating (0.5 Hz) and carrying frequencies (16.5 Hz), which is explained by the ratio A = A0sin omega1t + A0sin omega2t = A0sin(omega1 + omega2)t/2cos(omega1 - omega2)t/2. The efficiency of magnetic signals with pulsations (the sum of close frequencies) is more pronounced than that of sinusoidal frequencies. These data may indicate the presence of several receptors of weak magnetic fields in biological systems and, as a consequence, a higher efficiency of the effect at the simultaneous adjustment to these frequencies by the field. Even with consideration of these facts, the mechanism of the biological action of weak combined magnetic fields remains still poorly understood.

Download full-text PDF

Source

Publication Analysis

Top Keywords

magnetic fields
16
weak combined
12
biological action
8
action weak
8
weak magnetic
8
alternating component
8
combined magnetic
8
biological systems
8
sum close
8
close frequencies
8

Similar Publications

Optically pumped magnetometers (OPMs) functioning in the spin-exchange relaxation-free (SERF) regime have emerged as attractive options for measuring weak magnetic fields, owing to their portability and remarkable sensitivity. The operation of SERF-OPM critically relies on the ambient magnetic field; thus, a magnetic field compensation device is commonly employed to mitigate the ambient magnetic field to near zero. Nonetheless, the bias of the OPM may influence the compensation impact, a subject that remains unexamined.

View Article and Find Full Text PDF

The electronic structure characteristics of bilayer graphyne, bilayer graphdiyne, and bilayer graphtriyne were systematically studied using molecular orbital (MO) analysis, density of states (DOS), and interaction region indicator (IRI) methods. The delocalization characteristics of the out-of-plane and in-plane π electrons (i.e.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effectiveness of Fascial Manipulation in patients with disc herniations of the lumbar spine confirmed by magnetic resonance imaging. This study included 69 patients with intervertebral disc damage of the lumbar spine, as confirmed by magnetic resonance imaging. Patients were divided into two groups: a study group and a control group.

View Article and Find Full Text PDF

Equation for Calculation of Critical Current Density Using the Bean's Model with Self-Consistent Magnetic Units to Prevent Unit Conversion Errors.

Materials (Basel)

January 2025

Laboratory for Heteroepitaxial Growth of Functional Materials & Devices, Department of Chemical & Biological Engineering, State University of New York (SUNY) at Buffalo, Buffalo, NY 14260, USA.

This study analyzes the calculation of the critical current density by means of Bean's critical state model, using the equation formulated by Gyorgy et al. and other similar equations derived from it reported in the literature. While estimations of using Bean's model are widely performed, improper use of different equations with different magnetic units and pre-factors leads to confusion and to significant errors in the reported values of .

View Article and Find Full Text PDF

Microfluidic Integration of Magnetically Functionalized Microwires for Flow Cytometry Protein Quantification.

Materials (Basel)

January 2025

Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada.

A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are injected inside microfluidic channels and immobilized magnetically on the surface of glass-coated soft magnetic microwires placed along the symmetry axis of these channels. A fluorescent (Cy5) immunomagnetic sandwich ELISA is then performed by sequentially flowing the sample and all necessary reagents in the microfluidic channels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!