A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Body fat measured by a near-infrared interactance device as a predictor of cardiovascular events: the FINRISK'92 cohort. | LitMetric

We evaluated how body fat percentage, measured by a portable near-infrared interactance (NIR) device predicts cardiovascular (CVD), coronary heart disease (CHD), and ischemic stroke events in a prospective population-based survey. The study population consisted of 2,842 men and 3,196 women, who participated in the FINRISK'92 survey. Obesity was assessed with BMI, waist circumference, and waist-to-hip ratio (WHR) and body fat percentage measured with an NIR. Mean length of follow-up was 9 years and 3 months. In Cox proportional hazards regression analyses for men, BMI, waist circumference, and WHR as well as body fat percentage were predictors of a CVD event when adjusted for age and for major risk factors. Hazard ratio (HR) per 1 s.d. was 1.27 (95% confidence interval: 1.10-1.48) for body fat percentage, 1.30 (1.16-1.46) for BMI, and 1.31 (1.16-1.50) for waist circumference. Among women, the body fat lost its predictive power in a fully adjusted model. Body fat percentage, BMI, waist circumference, and WHR were predictors of a CHD event both among men and women, whereas body fat percentage did not predict ischemic stroke among either gender. We observed that body fat percentage measured by an NIR device was a significant predictor of CVD and CHD events among men and women, but in our population-based survey, it did not provide any additional predictive power over and above the simpler measures, such as BMI or WHR.

Download full-text PDF

Source
http://dx.doi.org/10.1038/oby.2010.236DOI Listing

Publication Analysis

Top Keywords

body fat
36
fat percentage
28
waist circumference
16
percentage measured
12
bmi waist
12
body
9
near-infrared interactance
8
device predictor
8
fat
8
nir device
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!