AI Article Synopsis

Article Abstract

Nosocomial blood stream infection (or nosocomial bacteremia) is a common problem in hospitals worldwide, including Malaysia. A three-year prospective cohort study (October 2003-March 2007) of the incidences, risk factors, and patterns of the microorganisms causing bacteremia was conducted using a validated surveillance form in three intensive care units (ICUs) in Malaysia. Center for Disease Control criteria were used to diagnose bacteremia. Patients were monitored from admission until the end point of study, which was the first detection of bacteremia in the blood in each patient. The frequency of occurrence of bacteremia with clinical symptoms was 10.7% (n=23). Bacteremia was observed to occur within a mean length of stay of 10 days in ICU. The rate of device-related infection was 10.4% per device utilization days with a device utilization rate of 95.9%/1000 patient days. The total number of patient days was 2309 and the period of device utilization was 2211 days. The common bacteria detected were extended-spectrum beta-lactamases (ESBLs) Klebsiella pneumoniae (n=6); Pseudomonas aeruginosa (n=6); Acinetobacter species (n=5); Methicillin-resistant Staphylococcus aureus (MRSA)(n=3); and (non- ESBL) Klebsiella pneumoniae (n=2). Multivariable analysis using Cox Proportional Hazard Model showed that the predictors for developing bacteremia were cancer, MRSA carriage, duration of central venous catheter (CVC) infusion, frequency change of CVC, and the administration of hydrocortisone drugs. These results indicate that a combination of nursing and medical interventions as well as patients' severity of illness could lead to bacteremia in ICU. Strategic implementation of quality assurance measures in ICUs could help to control this problem.

Download full-text PDF

Source

Publication Analysis

Top Keywords

device utilization
12
bacteremia
9
patient days
8
klebsiella pneumoniae
8
days
5
prospective surveillance
4
surveillance nosocomial
4
nosocomial device-associated
4
device-associated bacteremia
4
bacteremia three
4

Similar Publications

Objective: This study aimed to investigate the extent of gender disparities in financial interactions between neurosurgeons and the medical device industry, examining the differences in the number, amount, and types of payments made to male and female neurosurgeons.

Methods: Utilizing data from the Centers for Medicare & Medicaid Services Open Payments database covering 2016-2022, the authors conducted a comprehensive analysis of industry payments to neurosurgeons. This methodology included univariate and multivariate analyses to examine the disparities in payments, with a focus on identifying significant differences in compensation across genders.

View Article and Find Full Text PDF

We have successfully prepared a significant number of nanowires from non-toxic silicon sources. Compared to the SiO silicon source used in most other articles, our preparation method is much safer. It provides a simple and harmless new preparation method for the preparation of silicon nanowires.

View Article and Find Full Text PDF

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.

View Article and Find Full Text PDF

Background: Both glucagon-like peptide 1 receptor agonists (GLP-1 RAs) and continuous glucose monitoring (CGM) have been shown to improve glycated hemoglobin A1c (A1c) levels among patients with type 2 diabetes mellitus (T2DM). Recently, a US real-world study found statistically significant improvements in A1c levels among patients using GLP-1 RA and a CGM device, compared with a matched cohort receiving only GLP-1 RA.

Objectives: To assess the cost-effectiveness from a US payer perspective of initiating CGM (FreeStyle Libre Systems) in people living with T2DM using a GLP-1 RA therapy, compared with GLP-1 RA alone.

View Article and Find Full Text PDF

Based on nitrogen and phosphorus co-doped carbon dots (NP-CDs), a direct, quick, and selective sensing probe for fluorometric detection of rutin has been developed. Utilizing ethylene diamine tetra acetic acid (EDTA) as a carbon and nitrogen source and diammonium hydrogen phosphate (NH)HPO as a nitrogen and phosphorus source. The NP-CDs were synthesized in less than 3 min with a straightforward one-step microwave pyrolysis process with a high quantum yield (63.