Frequency-offset Cartesian feedback for MRI power amplifier linearization.

IEEE Trans Med Imaging

LitePoint Corporation, CA 94085, USA.

Published: February 2011

High-quality magnetic resonance imaging (MRI) requires precise control of the transmit radio-frequency (RF) field. In parallel excitation applications such as transmit SENSE, high RF power linearity is essential to cancel aliased excitations. In widely-employed class AB power amplifiers, gain compression, cross-over distortion, memory effects, and thermal drift all distort the RF field modulation and can degrade image quality. Cartesian feedback (CF) linearization can mitigate these effects in MRI, if the quadrature mismatch and dc offset imperfections inherent in the architecture can be minimized. In this paper, we present a modified Cartesian feedback technique called "frequency-offset Cartesian feedback" (FOCF) that significantly reduces these problems. In the FOCF architecture, the feedback control is performed at a low intermediate frequency rather than dc, so that quadrature ghosts and dc errors are shifted outside the control bandwidth. FOCF linearization is demonstrated with a variety of typical MRI pulses. Simulation of the magnetization obtained with the Bloch equation demonstrates that high-fidelity RF reproduction can be obtained even with inexpensive class AB amplifiers. Finally, the enhanced RF fidelity of FOCF over CF is demonstrated with actual images obtained in a 1.5 T MRI system.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3155726PMC
http://dx.doi.org/10.1109/TMI.2010.2087768DOI Listing

Publication Analysis

Top Keywords

cartesian feedback
12
mri
5
frequency-offset cartesian
4
feedback
4
feedback mri
4
mri power
4
power amplifier
4
amplifier linearization
4
linearization high-quality
4
high-quality magnetic
4

Similar Publications

Given the large amount of information that people process daily, it is important to understand memory for the truth and falsity of information. The most prominent theoretical models in this regard are the Cartesian model and the Spinozan model. The former assumes that both "true" and "false" tags may be added to the memory representation of encoded information; the latter assumes that only falsity is tagged.

View Article and Find Full Text PDF

Corrigendum to "Cartesian Control of Sit-to-Stand Motion Using Head Position Feedback".

Appl Bionics Biomech

October 2023

Electrical Engineering Department, Bahria University, Islamabad 44230, Pakistan.

[This corrects the article DOI: 10.1155/2020/1979342.].

View Article and Find Full Text PDF

This study presents the design of an adaptive event-driven controller for solving the trajectory tracking problem of a composite robotic device made up of a three-dimensional Cartesian and a parallel Delta robot. The proposed composite device has a mathematical model satisfying a standard Lagrangian structure affected by modeling uncertainties and external perturbations. The adaptive gain of the controller is considered to enforce the convergence of the tracking error while the state bounds are satisfied.

View Article and Find Full Text PDF

Recent advances in wearable sensors and computing have made possible the development of novel sensory augmentation technologies that promise to enhance human motor performance and quality of life in a wide range of applications. We compared the objective utility and subjective user experience for two biologically inspired ways to encode movement-related information into supplemental feedback for the real-time control of goal-directed reaching in healthy, neurologically intact adults. One encoding scheme mimicked visual feedback encoding by converting real-time hand position in a Cartesian frame of reference into supplemental kinesthetic feedback provided by a vibrotactile display attached to the non-moving arm and hand.

View Article and Find Full Text PDF

Somatosensation greatly increases the ability to control our natural body. This suggests that supplementing vision with haptic sensory feedback would also be helpful when a user aims at controlling a robotic arm proficiently. However, whether the position of the robot and its continuous update should be coded in a extrinsic or intrinsic reference frame is not known.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!