  • The study aimed to enhance the efficiency of a Cytogenetics lab by implementing Lean Management System initiatives to reduce long result turnaround times (TAT).
  • An analysis of 8040 bone marrow cases revealed that while 2915 required additional cell workup, only 49 cases confirmed the presence of a clone, suggesting most additional work was unnecessary.
  • The findings advocate for discontinuing extra workup procedures, as it would save time and resources, helping the lab to analyze more cases without compromising patient care, while encouraging the use of FISH or PCR assays for further case clarification.

Article Abstract

Introduction: High workload volumes in a Cytogenetics laboratory can lead to long result turn-around times (TAT). This study aimed to improve laboratory efficiency by adopting Lean Management System initiatives to increase productivity through the elimination of wastes. This study examined if the prerequisite 20-cell analysis was sufficient for a conclusive result or if additional cell workup was necessary to ascertain the presence of a previous chromosome abnormality among cases on follow-up, or when a single abnormal cell was encountered during the analysis to determine the presence of a clone.

Materials And Methods: The karyotype results of cases that had additional workup were retrieved from among 8040 bone marrow cases of various haematological disorders performed between June 2003 and June 2008.

Results: Of 8040 cases analysed, 2915 cases (36.3%) had additional cell workup. Only 49 cases (1.7%) led to the establishment of a clone. The majority of these cases could have been resolved without the additional workup, especially if fluorescence in situ hybridization (FISH) or polymerase chain reaction (PCR)-based assays had been utilised.

Conclusion: This study shows that the additional workup procedure is redundant. The time saved by discontinuing the workup procedure can be used to analyse other cases, leading to increased laboratory efficiency and a faster TAT without compromise to patient care. The practice of additional workup over and above the 20- cell analysis should be dispensed with as little benefit was derived for the amount of additional manpower expended. FISH or PCR-based assays should be utilised to elucidate a case further.

Download full-text PDF

Source

Publication Analysis

Top Keywords

additional workup
16
additional cell
12
cell workup
12
workup
9
bone marrow
8
lean management
8
management system
8
additional
8
laboratory efficiency
8
cases
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!