Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The validation of a high throughput and specific method using a high-performance liquid chromatography coupled to electrospray (ES+) ionization tandem triple quadrupole mass spectrometric (LC-ESI-MS/MS) method for ondansetron quantification in human plasma is described. Human plasma samples were extracted by liquid-liquid extraction (LLE) using methyl tert-butyl ether and analyzed by LC-ESI-MS/MS. The limit of quantification was 0.2 ng/mL and the method was linear in the range 0.2-60 ng/mL. The intra-assay precisions ranged from 1.6 to 7.7%, while inter-assay precisions ranged from 2.1 to 5.1%. The intra-assay accuracies ranged from 97.5 to 108.2%, and the inter-assay accuracies ranged from 97.3 to 107.0%. The analytical method was applied to evaluate the relative bioavailability of two pharmaceutical formulations containing 8 mg of ondansetron each in 25 healthy volunteers using a randomized, two-period crossover design. The geometric mean and respective 90% confidence interval (CI) of ondansetron test/reference percent ratios were 90.15% (81.74-99.44%) for C(max) and 93.11% (83.01-104.43%) for AUC(₀-t). Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) and AUC(₀-inf), it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of ondansetron.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bmc.1431 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!