A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants. | LitMetric

AI Article Synopsis

  • Total hip arthroplasty is a common surgery for severe hip osteoarthritis, but issues like aseptic loosening of implants due to stress shielding have led to the development of new materials for hip prostheses.
  • A study used a three-dimensional finite element model to compare a novel carbon-fibre polyamide composite hip stem with two existing metal hip stems (Exeter and Omnifit), applying a virtual axial load to analyze stress and strain.
  • Experimental results showed the composite stem had lower stress levels compared to the metal stems, but also lower stiffness, marking it as the first evaluation of this material's performance against traditional implants.

Article Abstract

Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R(2)=0.69, slope=0.82), Exeter (Pearson R(2)=0.78, slope=0.59), and Omnifit (Pearson R(2)=0.66, slope=0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2010.09.011DOI Listing

Publication Analysis

Top Keywords

hip stem
20
hip implants
16
hip
14
metallic hip
12
carbon-fibre hip
8
standard metallic
8
cf/pa12 carbon-fibre
8
stryker mahwah
8
mahwah usa
8
composite stem
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!