Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard.
Materials And Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard.
Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001).
Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00270-010-9992-x | DOI Listing |
Background and purpose The risk of rupture increases with advancing age. However, the risk-benefit of coil embolization for elderly patients with unruptured aneurysms is controversial. This study aimed to identify factors associated with treatment primary outcomes, including risk factors for complications and aneurysm recurrence requiring re-treatment in the endovascular treatment of unruptured aneurysms in elderly patients.
View Article and Find Full Text PDFBMC Gastroenterol
January 2025
Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Purpose: This study aimed to investigate the efficacy of measuring lymph node size on preoperative CT imaging to predict pathological lymph node metastasis in patients with colon cancer to enhance diagnostic accuracy and improve treatment planning by establishing more reliable assessment methods for lymph node metastasis.
Methods: We retrospectively analyzed 1,056 patients who underwent colorectal resection at our institution between January 2004 and March 2020. From this cohort, 694 patients with resectable colon cancer were included in the study.
Sci Rep
January 2025
School of Resources and Civil Engineering, Northeastern University, Shenyang, 110819, China.
Based on the symmetric initiation mechanism of double-wing cracks in coal rock mass induced by high-pressure electro-recoil water pressure, fracturing experiments have been performed on coal rock mass under different water pressures and discharge conditions using high-voltage electric pulse hydraulic fracturing devices. Combined with CT scans, the crack spatial distribution inside the post-break coal rock mass was analyzed and found that the edge of the water injection hole is prone to produce double-wing cracks along the drilling hole diameter. ABAQUS is used to verify the physical test and extend the test conditions, the geometric parameter change, morphological expansion rule and crack initiation mechanism of double-wing crack in coal rock mass under different discharge conditions and ground stress conditions are studied.
View Article and Find Full Text PDFExpert Rev Anticancer Ther
January 2025
Department of Biomedical Science, Humanitas University, Pieve Emanuele, Milan, Italy.
Small renal masses (SRM), especially those under 7 cm pose significant diagnostic challenges when using conventional imaging (CT/MRI). PET/CT with [Zr]Zr-girentuximab offers a promising alternative in this setting by enabling molecular-level imaging. The ZIRCON trial, a phase 3 multicenter study, evaluated the diagnostic accuracy of [Zr]Zr-girentuximab PET/CT in detecting clear cell renal cell carcinoma (ccRCC) in SRM.
View Article and Find Full Text PDFRadiol Phys Technol
January 2025
Department of Radiotherapy, Sri Shankara Cancer Hospital and Research Centre, 1st Cross, Shankarapuram, Basavanagui, Bengaluru, 560004, Karnataka, India.
This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!