Inadequately performed hand hygiene and non-disinfected surfaces are two reasons why the keys and mouse-buttons of laptops could be sources of microbial contamination resulting consequently in indirect transmission of potential pathogens and nosocomial infections. Until now the question has not been addressed whether the ventilation-blowers in laptops are actually responsible for the spreading of nosocomial pathogens. Therefore, an investigational experimental model was developed which was capable of differentiating between the microorganisms originating from the external surfaces of the laptop, and from those being blown out via the ventilation-blower duct. Culture samples were taken at the site of the external exhaust vent and temperature controls were collected through the use of a thermo-camera at the site of the blower exhaust vent as well as from surfaces which were directly exposed to the cooling ventilation air projected by the laptop. Control of 20 laptops yielded no evidence of microbial emission originating from the internal compartment following switching-on of the ventilation blower. Cultures obtained at the site of the blower exhaust vent also showed no evidence of nosocomial potential. High internal temperatures on the inner surfaces of the laptops (up to 73°C) as well as those documented at the site of the blower exhaust vent (up to 56°C) might be responsible for these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2951100PMC
http://dx.doi.org/10.3205/dgkh000150DOI Listing

Publication Analysis

Top Keywords

exhaust vent
16
site blower
12
blower exhaust
12
nosocomial infections
8
laptop ventilation-blowers
4
ventilation-blowers potential
4
potential source
4
nosocomial
4
source nosocomial
4
infections patients?
4

Similar Publications

Excessive cavity pressure may result in a sand casting explosion, and corresponding measures should be adopted to prevent these consequences. In this study, the pressure variations in the cavity were first investigated based upon on-site testing by taking the resin contents into consideration, and then the evolution characteristics of sand casting explosion accidents were analyzed in depth by system dynamics, chaos theory, and the bow-tie model. When the resin contents are 1.

View Article and Find Full Text PDF

Introduction: A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers.

Methods: In this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations.

View Article and Find Full Text PDF

Assessing Methods for Replacement of Soiled Bedding Sentinels in Cage-level Exhaust IVC Racks.

J Am Assoc Lab Anim Sci

September 2023

Division of Veterinary Resources, Office of Research Services, National Institutes of Health, Bethesda, Maryland.

Soiled bedding sentinel programs have long been the cornerstone of rodent health monitoring surveillance. Many recent studies have evaluated methods to replace live animals in these programs; however, the type of ventilated rack being used greatly influences the detection rate of adventitious pathogens. This study evaluated 4 alternative sampling techniques across 5 distinct vivaria and assessed their accuracy in detecting 5 pathogens.

View Article and Find Full Text PDF

Background: Airflow is an important issue to favor postharvest dehydration keeping wine grape quality. The aim of this experimental work was to analyze the grape quality during postharvest dehydration: (i) in a commercial facility ('fruttaia') by monitoring the efficiency of the ventilation system and (ii) at laboratory level, studying the influence of crate type and airflow direction.

Results: In the fruttaia, the airflow was provided by an air duct hanging from the ceiling, and by floor fans.

View Article and Find Full Text PDF

Origins of Oil and Gas Sector Methane Emissions: On-Site Investigations of Aerial Measured Sources.

Environ Sci Technol

February 2023

Energy & Emissions Research Laboratory, Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, Ontario K1S 5B6, Canada.

Success in reducing oil and gas sector methane emissions is contingent on understanding the sources driving emissions, associated options for mitigation, and the effectiveness of regulations in achieving intended outcomes. This study combines high-resolution, high-sensitivity aerial survey data with subsequent on-site investigations of detected sources to examine these points. Measurements were performed in British Columbia, Canada, an active oil- and gas-producing province with modern methane regulations featuring mandatory three times per year leak detection and repair (LDAR) surveys at most facilities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!