The timing jitter performance of a 5 GHz quantum dot passively mode-locked laser is investigated at different harmonics in the RF spectrum. The necessity of measuring the phase noise at relatively large harmonic numbers is motivated experimentally in the context of determining the corner frequency, its correlation to the RF linewidth, and the related white noise plateau level. The single-sideband phase noise with an integrated timing jitter of 211 fs (4-80 MHz) is reported. An all-microwave technique has been used to determine a pulse-to-pulse rms timing jitter of 96 fs/cycle. This low timing jitter value makes the chip-scale quantum dot mode-locked laser an attractive source for low noise applications such as optical clocking and sampling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.18.021932 | DOI Listing |
J Physiol
December 2024
Department of Otolaryngology - Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Kv channels generate A-type current known to regulate neuronal excitability. Its role in processing timing information is understudied, especially in the auditory system where temporal information is crucial for hearing. In the cochlear nucleus, principal bushy neurons are specialized for temporal processing with distinct biophysical properties owing to their expression of various voltage-gated ion channels.
View Article and Find Full Text PDFWe propose a timing jitter measurement scheme based on the temporal sampling method. This scheme offers a wide dynamic range and high measurement accuracy for measuring timing jitter between pulses, allowing for attosecond precision in measuring timing jitter of ultrashort pulses with short and long pulse duration. By utilizing a balanced measuring configuration, this scheme is naturally immune to the environmental and laser amplitude noises, and has been successfully used to measure timing jitter of two femtosecond pulses.
View Article and Find Full Text PDFWe introduce the world's first SPAD family design in 130 nm SiGe BiCMOS process. At 1.8 µm, we achieved the smallest pitch on record thanks to guard-ring sharing techniques, while keeping a relatively high fill factor of 24.
View Article and Find Full Text PDFPhase noise characteristics of ultrafast fiber lasers are critical to practical applications, such as high-resolution photonics sampling. Herein, we investigated the impact of pump power and linear phase shift difference of counter-propagating light in the nonlinear amplifying loop mirror on phase noise suppression in a figure-9 fiber laser. Based on these results, we proposed a method for intelligent suppression of phase noise through real-time feedback control.
View Article and Find Full Text PDFFront Psychol
September 2024
Laboratory of Neurophysiology and Movement Biomechanics, UNI - ULB Neuroscience Institute, Université Libre de Bruxelles (ULB), Brussels, Belgium.
Video presentation has become ubiquitous in paradigms investigating the neural and behavioral responses to observed actions. In spite of the great interest in uncovering the processing of observed bodily movements and actions in neuroscience and cognitive science, at present, no standardized set of video stimuli for action observation research in neuroimaging settings exists. To facilitate future action observation research, we developed an open-access database of 135 high-definition videos of a male actor performing object-oriented actions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!