Purpose: Treatment of intracranial tumors near the corticospinal tract remains a surgical challenge. Several technical tools to map and monitor the motor tract have been implemented. The present study aimed to assess the utility of diffusion tensor imaging (DTI) fiber tracking in the surgical treatment of motor eloquent tumors at our institution.

Methods: Patients operated for intracranial tumors close to the motor tract with the use of intraoperative image guidance including DTI fiber tracking of the corticospinal tract and intraoperative motor evoked potential (MEP) monitoring were analyzed. The intraoperative utility of fiber tracking data was analyzed. Furthermore, preoperative MRI scans with and without motor fiber tracking were reevaluated post hoc for tumor relation to the motor tract, estimated resectability, and best approach. Thereby, the utility of fiber tracking in surgical planning was assessed.

Results: Nineteen patients were analyzed. The estimation of tumor localization in relation to the motor tract and of resectability was not influenced by fiber tracking in any of the cases. Only in one single case did evaluating surgeons change their surgical approach after the addition of the fiber tracking data. In all cases, fiber tracking included in image guidance did not change the intraoperative strategy, while MEP monitoring did.

Conclusions: DTI fiber tracking did not influence the surgical planning or the intraoperative course. However, it is still used at our institution due to its ease in acquisition and its potential impact in a larger series. Furthermore, more experience with this technique is required to lead to a technical improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00701-010-0817-0DOI Listing

Publication Analysis

Top Keywords

fiber tracking
40
motor tract
16
intracranial tumors
12
corticospinal tract
12
dti fiber
12
fiber
10
tracking
10
utility diffusion
8
motor
8
motor fiber
8

Similar Publications

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance.

Anal Chem

January 2025

Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.

View Article and Find Full Text PDF

High-Performance Mechano-Sensitive Piezoelectric Nanogenerator from Post-Treated Nylon-11,11 Textiles for Energy Harvesting and Human Motion Monitoring.

ACS Appl Mater Interfaces

January 2025

School of Materials Science and Engineering, Henan Key Laboratory of Advanced Nylon Materials and Application, Zhengzhou University, Zhengzhou 450001, China.

Piezoelectric polymer textiles offer distinct advantages in the fabrication of wearable nanogenerators (NGs). One effective strategy to enhance the output capacity of NGs is to modulate the piezoelectric performance of the textiles. This paper focuses on further improving the piezoelectric properties of nylon-11,11 textiles through post-drawing and annealing treatments.

View Article and Find Full Text PDF

This paper experimentally investigates the impact response of composite laminates made with conventional and bio-based epoxy resin. Drop tower impact tests were conducted at varying energy levels, including repeated low-energy impacts, to evaluate perforation resistance. The laminates' residual strength and damage tolerance were assessed using the Damage Index (DI) and by analysing the resonance frequency variations through the Impulse Excitation Technique (IET).

View Article and Find Full Text PDF

Tissue Paper Softness: A Comparison Between Different Experimental Assessment Approaches.

Materials (Basel)

January 2025

Fiber Materials and Environmental Technologies Research Unit (FibEnTech-UBI), University da Beira Interior, R. Marquês D'Ávila e Bolama, 6201-001 Covilhã, Portugal.

In this work, four different experimental assessment approaches, namely, the Tissue Softness Analyzer (TSA), a Subjective Evaluation (SUB), the Kawabata Evaluation System (KES), and an Optical System (OPT), were used for the evaluation of softness on a set of 29 different tissue paper products. After processing and the interpretation of the results given by each one of the used methods, a procedure was implemented in the current work to make a comparison between them. The procedure consists in tracking the position of the tissue paper products on a ranking table, regardless of what values were obtained through each one of the four used methods independently.

View Article and Find Full Text PDF

Background: Spinal muscular atrophy (SMA) is caused by reduced expression of survival motor neuron (SMN) protein. Previous studies indicated SMA causes not only lower motor neuron degeneration but also extensive brain involvement. This study aimed to investigate the changes of brain white matter and structural network using diffusion tensor imaging (DTI) in children with type 2 and 3 SMA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!