A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging. | LitMetric

Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging.

IEEE Trans Biomed Eng

Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam 1100DE, The Netherlands.

Published: January 2011

Malunion after a distal radius fracture is very common and if symptomatic, is treated with a so-called corrective osteotomy. In a traditional distal radius osteotomy, the radius is cut at the fracture site and a wedge is inserted in the osteotomy gap to correct the distal radius pose. The standard procedure uses two orthogonal radiographs to estimate the two inclination angles and the dimensions of the wedge to be inserted into the osteotomy gap. However, optimal correction in 3-Dspace requires restoring three angles and three displacements. This paper introduces a new technique that uses preoperative planning based on 3-D images. Intraoperative 3-D imaging is also used after inserting pins with marker tools in the proximal and distal part of the radius and before the osteotomy. Positioning tools are developed to correct the distal radius pose in six degrees of freedom by navigating the pins. The method is accurate ( d 1.2 mm, ϕ 0.9°, m TRE = 1.7 mm), highly reproducible (SE (d) < 1.0 mm, SE (ϕ) ≤ 1.4°, SE (m) (TRE) = 0.7 mm), and allows intraoperative evaluation of the end result. Small incisions for pin placement and for the osteotomy render the method minimally invasive.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2010.2084576DOI Listing

Publication Analysis

Top Keywords

distal radius
24
radius osteotomy
12
wedge inserted
8
inserted osteotomy
8
osteotomy gap
8
correct distal
8
radius pose
8
radius
7
osteotomy
7
distal
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!