A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Randomised clinical trial comparing pressure characteristics of pelvic circumferential compression devices in healthy volunteers. | LitMetric

Introduction: The role of pelvic circumferential compression devices (PCCDs) is to temporarily stabilise a pelvic fracture, reduce the volume and tamponade the bleeding. Tissue damage may occur when PCCDs are left in place longer than a few hours. The aim of this randomised clinical trial was to quantify the pressure at the region of the greater trochanters (GTs) and the sacrum, induced by PCCDs in healthy volunteers.

Materials And Methods: In a crossover study, the Pelvic Binder(®), SAM-Sling(®) and T-POD(®) were applied successively onto 80 healthy participants in random order. The pressure was measured using a pressure mapping system, with the volunteers in supine position on a spine board and on a hospital bed. Data were analysed using Mixed Linear Modelling.

Results: On a spine board, the pressure exceeded the tissue damaging threshold at the GTs and the sacrum. Pressure at the GTs was highest with the Pelvic Binder(®), and lowest with the SAM-Sling(®). Pressure at the sacrum was highest with the Pelvic Binder(®). The pressure at the GTs and sacrum was reduced significantly for all three PCCDs upon transfer to a hospital bed.

Conclusion: The results of this randomised clinical trial in healthy volunteers showed that patients with pelvic fractures, temporarily stabilised with a PCCD, are at risk for developing pressure sores. The pressure on the skin exceeded the tissue damaging threshold and is, besides PCCD type, influenced by BMI, waist size and age. Regardless with which PCCD trauma patients are stabilised, early transfer from the spine board is of key importance to reduce the pressure to a level below the tissue damaging threshold. Clinicians should be aware of the potential deleterious effects associated with the application of a PCCD, and every effort must be made to remove the PCCD once haemodynamic resuscitation has been established.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2010.09.011DOI Listing

Publication Analysis

Top Keywords

randomised clinical
12
clinical trial
12
gts sacrum
12
pelvic binder®
12
spine board
12
tissue damaging
12
damaging threshold
12
pressure
11
pelvic circumferential
8
circumferential compression
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!