The objectives of this work were to compare enterococci (ENT) measurements based on the membrane filter, ENT(MF) with alternatives that can provide faster results including alternative enterococci methods (e.g., chromogenic substrate (CS), and quantitative polymerase chain reaction (qPCR)), and results from regression models based upon environmental parameters that can be measured in real-time. ENT(MF) were also compared to source tracking markers (Staphylococcus aureus, Bacteroidales human and dog markers, and Catellicoccus gull marker) in an effort to interpret the variability of the signal. Results showed that concentrations of enterococci based upon MF (<2 to 3320 CFU/100 mL) were significantly different from the CS and qPCR methods (p < 0.01). The correlations between MF and CS (r = 0.58, p < 0.01) were stronger than between MF and qPCR (r ≤ 0.36, p < 0.01). Enterococci levels by MF, CS, and qPCR methods were positively correlated with turbidity and tidal height. Enterococci by MF and CS were also inversely correlated with solar radiation but enterococci by qPCR was not. The regression model based on environmental variables provided fair qualitative predictions of enterococci by MF in real-time, for daily geometric mean levels, but not for individual samples. Overall, ENT(MF) was not significantly correlated with source tracking markers with the exception of samples collected during one storm event. The inability of the regression model to predict ENT(MF) levels for individual samples is likely due to the different sources of ENT impacting the beach at any given time, making it particularly difficult to to predict short-term variability of ENT(MF) for environmental parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2966524PMC
http://dx.doi.org/10.1021/es100884wDOI Listing

Publication Analysis

Top Keywords

evaluation conventional
4
conventional alternative
4
alternative monitoring
4
monitoring methods
4
methods recreational
4
recreational marine
4
marine beach
4
beach nonpoint
4
nonpoint source
4
source fecal
4

Similar Publications

Objective(s): Some forms of breast cancer such as triple-negative phenotype, are serious challenge because of high metastatic cases, high mortality and resistance to conventional therapy motivated the search for alternative treatment approaches. Nanomaterials are promising candidates and suitable alternatives for improving tumor and cancer cell treatments.

Materials And Methods: Biosynthesis of ZnO NPs by help of Berberis integerrima fruit extract, has been done.

View Article and Find Full Text PDF

Objective: The study compares and evaluates planned virtual outcomes with actual post-treatment outcomes to assess the accuracy and predictability of clinical results during presurgical infant orthopaedics (PSIO) with AlignerNAM in infants with unilateral cleft lip and palate.

Setting: Institutional study.

Participants: 14 UCLP patients.

View Article and Find Full Text PDF

Background: Venous thromboembolism (VTE) is a common complication after hip arthroplasty. Here, we investigated the clinical efficacy and safety of prophylactic aspirin vs. conventional therapy in hip arthroplasty for femoral neck fracture.

View Article and Find Full Text PDF

Objective: The purpose of this study was to evaluate MRI findings of ovarian endometrioid carcinoma (OEC) as a predictor of histological grade.

Materials And Methods: This study included 60 patients with histopathologically confirmed OEC (20, 30, and 10 with grades 1, 2, and 3, respectively). Clinical and MRI results were retrospectively reviewed.

View Article and Find Full Text PDF

Temporal-thermal enhancement of porous cooking burners.

Sci Rep

December 2024

Faculty of Mechanical Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran, Iran.

Porous combustion has drawn vast attention over the last few decades leading to a variety of progressing applications particularly in industrial kitchens and household appliances that require time sensitive heating. The present study experimentally investigates the relationship between cooking duration and the thermal efficiency of a cooking pot heated on a porous burner providing a valuable insights into the effectiveness of the heating process in terms of both time and fuel consumption. To facilitate this investigation, a dedicated test bench is designed and constructed, equipped with thermometers and timer to effectively monitor the temporal/thermal behavior of the heating process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!