Background: The aim of this study was to investigate the effect of applanation tonometry on the accuracy of biometric measurements and the reproducibility of keratometric measurements.
Patients And Methods: In this clinical prospective study a total of 16 patients were enrolled who presented for cataract surgery on 30 eyes. Biometry measurements were made using an IOLMaster optical biometer before and 10 min after standard Goldmann applanation tonometry. Local anesthesia was achieved by administering one drop of fluorescein-stained oxybuprocaine 0.4%.
Results: The mean absolute difference of intraocular lens power for emmetropia was 0.31 ± 0.33 D (range -1.56 to +1.12 D) and the mean standard deviation for R1 and R2 (n=28 eyes) was 0.014 ± 0.013 mm before and 0.024 ± 0.021 mm after tonometry. This difference was statistically significant (t-test, p<0.01). Moderate to severe irregular corneal surfaces were noted in some cases after tonometry.
Conclusions: Local anesthesia and applanation tonometry reduced the accuracy of IOL power calculations with differences exceeding ± 1 D and the reliability of consecutive keratometry measurements decreased significantly. Therefore, it is advisable to perform biometry measurements at the very beginning of the preoperative examination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00347-010-2240-6 | DOI Listing |
Transl Vis Sci Technol
December 2024
Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
Purpose: This study aims to perform a clinical investigation of an innovative rebound technology-based device, the M-TONX, to simultaneously measure intraocular pressure (IOP) and central corneal thickness (CCT).
Methods: The IOP and CCT of the patients were first measured by the M-TONX. Then, the measurements were repeated by the Goldman applanation (GAT) and the Pentacam corneal topographer, as the standard devices.
Graefes Arch Clin Exp Ophthalmol
December 2024
Kaiya Eye Clinic, Hamamatsu, Shizuoka, Japan.
Purpose: Little is known about the effects of ambient atmospheric pressure (AP) on intraocular pressure (IOP) under ordinary conditions. This study aimed to investigate the effects of AP on Goldmann applanation tonometer-measured IOP (GAT-IOP) in normal eyes under everyday atmospheric conditions adjusting for effects of possible confounding factors including other climatic factors.
Methods: Data obtained from 2,431 normal healthy eyes of 2,431 subjects (mean age: 56.
J Clin Med
November 2024
2nd Department of Ophthalmology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Intraocular pressure (IOP) readings using three different methods (Goldmann applanation tonometry (GAT), Corvis ST, and iCare) were compared in patients who underwent penetrating keratoplasty (PK). : An observational cross-sectional study with prospective recruitment of patients was conducted. IOP measurements were acquired using GAT, iCare, and Corvis (including both uncorrected IOP (CVS-IOP) and biomechanical IOP (bIOP)), and the agreement among methods was analyzed using Bland-Altman plots.
View Article and Find Full Text PDFNefrologia (Engl Ed)
December 2024
Unidad de Factores de Riesgo Vascular, Hospital Universitario, Jerez de la Frontera, Cádiz, Spain. Electronic address:
Rationale And Objectives: Increased aortic or central arterial stiffness (CAS) is a major factor in cardiovascular morbidity and mortality in patients with vascular risk factors. Decreased glomerular filtration rate (GFR) and increased urinary albumin excretion (uALB) are associated with lethal and non-lethal cardiovas-cular events. The pathophysiological mechanisms of this association are not fully defined.
View Article and Find Full Text PDFInt Ophthalmol
December 2024
Clinic of Ophthalmology, Mersin State Hospital, Mersin, Turkey.
Purpose: To evaluate the effect of upper eyelid blepharoplasty with or without the removal of a strip of orbicularis oculi muscle on corneal topographic parameters, anterior segment parameters, intraocular pressure, and ocular biometry.
Method: This prospective study examined 428 eyes of 214 patients with dermatochalasis. Patients were divided into two groups randomly: those who underwent orbicularis oculi muscle excision (Group 1) during blepharoplasty and those who did not (Group 2).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!