Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0104-11692010000400018 | DOI Listing |
Rev Lat Am Enfermagem
November 2010
Hospital Alemão Oswaldo Cruz, Universidade de Sao Paulo, Brasil.
Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
May 2006
Center for Biosystems Research, University of Maryland Biotechnology Institute, 5115 Plant Sciences Building, College Park, Maryland 20742, USA.
An adhesive that cures under moist/wet conditions could facilitate surgical procedures for retinal reattachment. We are investigating an adhesive that mimics the factor XIIIa-mediated crosslinking of fibrin that occurs in the late stages of the blood coagulation cascade. Specifically, we use gelatin as the structural protein (in place of fibrin), and crosslink gelatin using a calcium-independent microbial transglutaminase (in place of the calcium-dependent transglutaminase factor XIIIa).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!