We characterize inductors fabricated from ultra-thin, approximately 100 nm wide strips of niobium (Nb) and niobium nitride (NbN). These nanowires have a large kinetic inductance in the superconducting state. The kinetic inductance scales linearly with the nanowire length, with a typical value of 1 nH µm(-1) for NbN and 44 pH µm(-1) for Nb at a temperature of 2.5 K. We measure the temperature and current dependence of the kinetic inductance and compare our results to theoretical predictions. We also simulate the self-resonant frequencies of these nanowires in a compact meander geometry. These nanowire inductive elements have applications in a variety of microwave frequency superconducting circuits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0957-4484/21/44/445202 | DOI Listing |
Rev Sci Instrum
January 2025
NASA Goddard Space Flight Center, Greenbelt, Maryland 20771, USA.
This work describes the design and implementation of optics for EXCLAIM, the EXperiment for Cryogenic Large-Aperture Intensity Mapping. EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbon monoxide at redshifts z < 1 and ionized carbon ([CII]) at redshifts z = 2.5 - 3.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Laboratorio de Circuitos Integrados (LABIC), Departamento de Electrónica, Área de Instrumentación, Instituto de Astrofísica de Canarias (IAC), 38205 La Laguna, Tenerife, Spain.
The use of non-cryogenic certified commercial electronics for cryogenic applications may be attractive due to their cost and availability, but it also carries risks related to reliability, performance and thermal compatibility. The decision to use commercial components that are not certified for cryogenics instead of components specifically designed for such applications must be carefully weighed based on specific project needs and risk tolerances. This work presents the characterisation of an attenuator circuit at cryogenic temperatures used in a microwave kinetic inductance detector (MKID) readout system.
View Article and Find Full Text PDFRev Sci Instrum
November 2024
Department of Physics, University of California, Santa Barbara, California 93106, USA.
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of single-photon counting with energy resolution across the ultraviolet, optical, and infrared (UVOIR) spectrum with microsecond timing precision. MKIDs are also multiplexable, providing a feasible way to create large-format, cryogenic arrays for sensitive imaging applications in biology, astronomy, and quantum information. Building large, cryogenic MKID arrays requires processing highly multiplexed, wideband readout signals in real time; this task has previously required large, heavy, and power-intensive custom electronics.
View Article and Find Full Text PDFNanomaterials (Basel)
October 2024
Institute of Superconductivity, Department of Physics, Bar-Ilan University, Ramat-Gan 5290002, Israel.
We present a MgB-based Microwave Kinetic Inductance Detector (MKID) featuring a quality factor Q ~ 10 and noise equivalent power NEP ~ 10 W/Hz at 2 K. In comparison to YBCO-based MKIDs, the MgB detector shows greater sensitivity to both temperature and magnetic field, a result of its two-gap nature and relatively low critical Hc2 field. Our data indicate that MgB is more advantageous for MKID applications at temperatures lower than 3 K.
View Article and Find Full Text PDFSingle-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!