Background: Instrumented circumferential fusion has been used as a primary and salvage procedure in lumbar spine fusion, especially for adult low-grade isthmic spondylolisthesis. Recently, instrumented anterior lumbar interbody fusion (ALIF) has been shown to provide good clinical and radiologic results that are comparable with those attained with traditional lumbar fusion. However, there have been no reports available that compare instrumented circumferential fusion with instrumented ALIF.
Methods: Between January 2003 and November 2004, a total of 43 consecutive patients underwent instrumented ALIF (group I) at one hospital of the authors. Between February 2003 and October 2006, a total of 32 consecutive patients underwent instrumented circumferential fusion (group II) at the other hospital of the authors. The authors retrospectively reviewed clinical and radiologic data from patients. The time spent on the operation, blood loss, blood transfusions, the length of hospital stay, complications, clinical results, and radiologic results, including disc height (DH), degree of listhesis, segmental lordosis (SL), and whole lumbar lordosis (WL), were analyzed and compared. Clinical outcomes were graded using visual analog scale (VAS) scores. Functional outcomes were measured using Oswestry Disability Index (ODI) scores and return-to-work status.
Results: The mean follow-up period was 41.1 and 32.9 months in group I and group II, respectively. Radiologic evidence of fusion was noted in 42 of 43 patients in group I and in 32 of 32 patients in group II. In both groups, all of the radiologic data, including the DH, degree of listhesis, SL, and WL significantly changed from the preoperative to postoperative period except for WL in group II. In both groups, VAS scores for back and leg pain and ODI scores significantly changed from the preoperative to postoperative period. There was no significant difference for VAS scores for back ODI scores in the two treatment groups after surgery. The mean time until return to work was 3.7 months in group I and 3.6 months in group II (p < .05). The mean hospital stay for group I (7.4 days) was shorter than that for group II (15.2 days) (p < .05). The mean operation time in group I (190 minutes) was shorter than that in group II (260.8 minutes) (p < .05). The mean blood loss in group I (300 mL) was less than that in group II (379 mL) (p < .05).
Conclusions: According to the present clinical outcome, instrumented ALIF is at least as effective as instrumented circumferential fusion for the treatment of back pain in adult patients with low-grade isthmic spondylolisthesis. Moreover, in terms of operative data including the duration of operation and hospital stay, as well as blood loss, instrumented ALIF demonstrates better results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2010.02.057 | DOI Listing |
Acta Biomater
December 2024
Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, NTNU, Norway. Electronic address:
During gastric surgery, the stomach wall is compressed with clamps and sutures or staple lines. These short- and long-term deformations can severely compromise the integrity of the tissue and make it difficult for the stomach wall to respond and remodel to the new loading conditions. Consequently, serious intra- and postoperative complications such as the formation of leaks during bariatric surgeries, can be associated with these immense tissue deformations.
View Article and Find Full Text PDFCureus
November 2024
Surgical Oncology, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA.
Minimally invasive surgery, especially robotic surgery, has become increasingly popular in colorectal surgery over the last decade. Robotic-assisted surgery has shown better outcomes than conventional laparoscopic surgery because of superior ergonomics, high-resolution three-dimensional cameras, and articulating instruments; however, issues like the long operative time and cost-effectiveness remain unresolved. This study compares the robotic and laparoscopic approach of abdominoperineal resection (APR) for low rectal cancer to evaluate the superiority of robotic surgery in short-term and oncological outcomes.
View Article and Find Full Text PDFOver the past 15 years, there has been a shift toward meniscus preservation even for previously believed irreparable patterns like bucket handle, radial, meniscus root, vertical, and horizontal cleavage tears (HCTs). HCTs are a common tear pattern, especially as we age, and are estimated to occur in 23% to 32% of meniscus tears. They occur in both males and females, are more common on the medial than the lateral side, and most often occur with minor to normal trauma in an anterior cruciate ligament intact knee.
View Article and Find Full Text PDFSurg Clin North Am
February 2025
Department of Surgery, Weill Cornell Medicine, 525 East 68th Street, Box 294, New York, NY 10065, USA. Electronic address:
A minimally invasive approach is the most common technique for hiatal hernia repair. The robotic platform offers a unique advantage that addresses the limitations of a laparoscopic repair. The steps of a robotic hiatal hernia repair include reduction of hernia contents, dissection of hernia sac, circumferential dissection of esophagus with 2.
View Article and Find Full Text PDFClin Implant Dent Relat Res
November 2024
Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.
Introduction: Implantoplasty can be performed on implants diagnosed with peri-implantitis to facilitate implant decontamination and improve access for oral home care. However, its effect on the mechanical strength of the implant is still uncertain. This study aimed to evaluate the effect of implantoplasty on the fracture resistance of dental implants with various degrees of bone loss, as well as its surface changes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!