A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

COLD PCR HRM: a highly sensitive detection method for IDH1 mutations. | LitMetric

The p.Arg132His mutation of isocitrate dehydrogenase 1 (IDH1(R132H) ) is a frequent alteration and a major prognostic marker in gliomas. However, direct sequencing of highly contaminated tumor samples may fail to detect this mutation. Our objective was to evaluated the sensitivity of a newly described amplification method, coamplification at lower temperature-PCR (COLD PCR), combined with high-resolution melting (HRM) for the detection of the IDH1(R132H) mutation. To this end, we used serial dilutions of mutant DNA with wild-type DNA. PCR-HRM assay detects IDH1(R132H) at an abundance of 25%, similar to the detection limit of direct Sanger sequencing. Introducing a run of COLD PCR allows the detection of 2% mutant DNA. Using two consecutive runs of COLD PCR, we detected 0.25% mutant DNA in a background of wild-type DNA, that mimics a tumor sample highly contaminated by normal DNA. We then analyzed 10 biopsies of tumor edges, considered free of tumor cells by histological analysis, and showed that immunohistochemistry of IDH1(R132H) was positive in three cases (30%), whereas double COLD PCR HRM was positive in the 10 cases studied (100%). In summary, COLD PCR HRM analysis is 100-fold more sensitive than Sanger sequencing, rendering this rapid and powerful strategy particularly useful for samples highly contaminated with normal tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1002/humu.21365DOI Listing

Publication Analysis

Top Keywords

cold pcr
24
pcr hrm
12
highly contaminated
12
mutant dna
12
wild-type dna
8
sanger sequencing
8
contaminated normal
8
cold
6
dna
6
pcr
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!