Purpose: To evaluate preliminary clinical results and lamellar and side cut obtained with a 60-kHz femtosecond laser (IntraLase) using a new software designed to create penetrating cuts for keratoplasty to perform the donor and recipient dissection in femtosecond laser-assisted endothelial keratoplasty.
Design: Prospective interventional case series.
Methods: A femtosecond laser set in a raster spot pattern was used to create the posterior lamellar dissection and posterior side cut in 4 donor corneas and in 4 recipient human eyes of 4 patients with endothelial decompensation. The laser cut was performed to obtain a 150-μm thick and 9-mm wide posterior lamellar disk from the donor and the recipient eyes. Postoperatively, patients underwent slit-lamp examination and Snellen visual acuity evaluation, Visante optical coherence tomography, optical pachymetry, and endothelial microscopy analysis. Three residual donor corneas were analyzed by scanning electron microscopy and transmission electron microscopy to observe the stromal bed surface, the side cut, and the effects of the laser dissection on the cornea ultrastructure.
Main Outcome Measures: Thickness of the implanted donor lamella, adhesion and clarity of the transplanted cornea in the postoperative follow-up, and smoothness of the interface.
Results: All the patients showed good adhesion and fit of the donor disk to the recipient and a circle side cut observed at the slit-lamp examination. Visante optical coherence tomography evaluation confirmed the adhesion and the precalibrated thickness of the implanted lamella. A good corneal transparency was achieved within the first 2-3 weeks. The scanning electron microscopy analysis showed a smooth stromal residual surface and a precise side cut. The transmission electron microscopy images showed that the laser randomly modified the structural design of the collagen fibers for approximately 10-μm depth, although below a regular stromal structure was maintained.
Conclusions: The 60-kHz IntraLase femtosecond laser creates a smooth stromal bed and precise side cut for endothelial keratoplasty. The posterior lamellar cut performed at the same depth in both the donor and the recipient makes it possible to create a corneal disk from the donor that fits exactly with the cut in the recipient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICO.0b013e3181ead924 | DOI Listing |
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Vet Surg
January 2025
University Equine Hospital, Swedish University of Agricultural Sciences, Uppsala, Sweden.
Objectives: To report the management and outcomes of five horses with ear skin defects treated with the use of full-thickness mesh grafts and full-thickness Meek micrografts.
Animals: Five horses with acute or granulating pinna skin wounds.
Study Design: Short case series.
Introduction: Kinematic alignment (KA) in total knee arthroplasty (TKA) is by definition a pure femoral resurfacing procedure aiming to restore the individual prearthritic anatomy. However, when a 2 mm compensation is systematically used on the worn side, the variability in cartilage thickness in the unworn compartment might alter the accuracy of the technique. This study aimed to validate two intraoperative femoral cartilage thickness measurement techniques by comparing them to the photographic method, which measures cartilage thickness through pixel analysis of bone-cut images.
View Article and Find Full Text PDFIndian J Psychiatry
December 2024
Department of Psychiatry, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Aim: This study aimed to evaluate the prevalence of obstructive sleep apnea (OSA) and its correlates among schizophrenia spectrum disorder patients receiving clozapine.
Methods: For this, 200 schizophrenia spectrum disorder patients receiving clozapine for at least one year were assessed on the Berlin Sleep Questionnaire for OSA.
Results: Around one-sixth of the study sample (16.
Medicina (Kaunas)
January 2025
Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
Proximal tibiofibular joint detachment (PTFJD) is a fibular untethering procedure during lateral closing-wedge high tibial osteotomy (LCWHTO) for varus knee osteoarthritis. However, the PTFJD procedure is technically demanding, and confirmation of clear joint separation is not straightforward. The aim of this study was to compare the degree of completion and safety of PTFJD versus tibial-sided osteotomy (TSO); this latter procedure is our novel technique for fibular untethering during LCWHTO.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!