Fully autonomous preload-sensitive control of implantable rotary blood pumps.

Artif Organs

Berlin Heart-R&D, Berlin, Germany.

Published: September 2010

A pulsatility-based control algorithm with a self-adapting pulsatility reference value is proposed for an implantable rotary blood pump and is to be tested in computer simulations. The only input signal is the pressure difference across the pump, which is deduced from measurements of the pump's magnetic bearing. A pulsatility index (PI) is calculated as the mean absolute deviation from the mean pressure difference. As a second characteristic, the gradient of the PI with respect to the pump speed is derived. This pulsatility gradient (GPI) is used as the controlled variable to adjust the operating point of the pump when physiological variables such as the systemic arterial pressure, left ventricular contractility, or heart rate change. Depending on the selected mode of operation, the controller is either a linear controller or an extremum-seeking controller. A supervisory mechanism monitors the state of the system and projects the system into the region of convergence when necessary. The controller of the GPI continuously adjusts the reference value for PI. An underlying robust linear controller regulates the PI to the reference value in order to take into account changes in pulmonary venous return. As a means of reacting to sudden changes in the venous return, a suction detection mechanism was included. The control system is robustly stable within a wide range of physiological variables. All the clinician needs to do is to select between the two operating modes. No other adjustments are required. The algorithm showed promising results which encourage further testing in vitro and in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2010.01092.xDOI Listing

Publication Analysis

Top Keywords

implantable rotary
8
rotary blood
8
pressure difference
8
physiological variables
8
linear controller
8
venous return
8
controller
5
fully autonomous
4
autonomous preload-sensitive
4
preload-sensitive control
4

Similar Publications

This study compared the apical transportation and centering ratio of ProTaper Next (PTN) and XP-endo Shaper (XPS) nickel titanium (NiTi) rotary files in curved root canals using cone beam computed tomography (CBCT). The current in vitro study involved the mesiobuccal canals of mesial roots in 44 extracted mandibular first molars that exhibited apical curvature ranging from 10° to 30°. Two experimental groups were randomly formed from the teeth ( = 22) and subjected to instrumentation with PTN and XPS.

View Article and Find Full Text PDF

Effect of mechanical instrumentation on titanium implant surface properties.

Dent Mater

January 2025

Department of Materials, School of Natural Sciences, University of Manchester, Manchester M13 9PL, UK; Photon Science Institute, University of Manchester, Manchester M13 9PL, UK. Electronic address:

Objective: To assess the impact of mechanical decontamination using rotary brushes on the surface topography, elemental composition, roughness, and wettability of titanium implant surfaces.

Methods: Four commercially available rotary brushes were used: Labrida BioClean Brush® (LB), i-Brush1 (IB), NiTiBrush Nano (NiTiB), and Peri-implantitis Brush (PIB). Seventy-five titanium discs with sandblasted, large-grit, acid-etched (SLA) surfaces were randomly assigned to five groups (n = 15): LB, IB, NiTiB, PIB, and a control group.

View Article and Find Full Text PDF

Purpose: To evaluate whether there are clinical benefits by preparing dental implant sites using piezosurgery instead of conventional rotary drills in healed bone crests and if initial crestal soft tissue thickness could have an impact on marginal bone loss.

Methods: Twenty-five partially edentulous patients requiring two single implants in molar/premolar areas had each site randomly allocated to either piezosurgery or to conventional rotary drill preparation according to a split-mouth design. Definitive screw-retained metal-ceramic crowns were delivered after 6 months.

View Article and Find Full Text PDF

Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta.

View Article and Find Full Text PDF

Culturing 3D chitosan/gelatin/nano-hydroxyapatite and bone-derived scaffolds in a dynamic environment enhances osteochondral reconstruction.

Int J Biol Macromol

December 2024

State Key Laboratory of Fine Chemicals, Dalian R&D Center for Stem Cell and Tissue Engineering, Dalian University of Technology, Dalian 116024, China. Electronic address:

Bioreactor can provide a dynamic culture environment for the in vitro construction of osteochondral tissue engineering. They facilitate more efficient exchange of nutrients and provide mechanical and other beneficial stimulation. Previous findings demonstrated that rotary flask (RF) bioreactor, rotary cell culture system (RCCS), or electromagnetic field (EMF) mediated scaffold culture could create a favorable dynamic environment for osteochondral tissue engineering.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!