Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/AIA.0b013e3181f89b10 | DOI Listing |
Biomaterials
January 2025
School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju, 61005, Republic of Korea. Electronic address:
Peripheral nerve injuries impair quality of life due to pain and loss of sensory and motor functions. Current treatments like autografts and nerve guidance conduits (NGCs) have limitations in functional restoration. Luminal fillers can enhance the effectiveness of NGCs by providing beneficial intraneural environments.
View Article and Find Full Text PDFBr J Anaesth
February 2025
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA; CEU-San-Pablo University School of Medicine, Madrid, Spain; Department of Anesthesiology, Madrid-Montepríncipe University Hospital, Madrid, Spain. Electronic address:
Background: We investigated the intraneural spread of injected fluid in brachial plexus nerve roots, examining the potential for intrafascicular spread and identifying influencing factors.
Methods: Twelve deliberate ultrasound-guided intraneural injections were performed at the ventral rami of the brachial plexus nerve roots at their exits from the neuroforamina in six fresh, unembalmed, cryopreserved human cadavers. A 22-G, 30-degree bevel echogenic regional anaesthesia needle was used.
Reg Anesth Pain Med
January 2025
Anesthesia, Ospedale Regionale di Bellinzona e Valli Bellinzona, Bellinzona, Switzerland.
Neuromodulation
November 2024
Laboratory of Energy and Data Science, Division of Smart Sector Integration, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Casaccia Research Center, Rome, Italy. Electronic address:
Objectives: This study introduces EMPATIC (Electro-Modulation of PAncreaTic Islet Cells), a miniaturized intraneural device designed for transversal insertion into small nerves with a mean diameter of 400 μm. EMPATIC aims to modulate glucose tolerance through intraneural vagus nerve stimulation (VNS) in rats.
Materials And Methods: EMPATIC design was optimized to fit into the cervical vagus nerve of rats and was developd through thin film microtechnologies.
Nucl Med Biol
November 2024
Amsterdam UMC location Vrije Universiteit Amsterdam, Dept Radiology & Nuclear Medicine, De Boelelaan 1117, Amsterdam, the Netherlands; Amsterdam Neuroscience, Brain Imaging, Amsterdam, the Netherlands. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!