Objective: To investigate risks and clinical effects of operative treatment for cervical vertebral fracture and dislocation associated with unilateral vertebral artery injury.

Methods: This group consisted of 76 cases of closed cervical spine trauma combined with unilateral vertebral artery injury (23 cases of bilateral facet dislocation, 28 unilateral facet dislocation and 25 fracture). All patients underwent prospective examination of cervical spine MRI and vertebral artery two-dimensional time-of-flight (2D TOF) magnetic resonance angiography (MRA), and anterior cervical decompression. The healthy vertebral artery paths were evaluated before the surgery, and were protected during the surgery according to the anatomical signs.

Results: There were no acute or chronic clinical damage symptoms in 76 cases after surgery. No neural damage symptoms were observed in patients with normal neural functions. The neural functions of incomplete paralyzed patients were improved in different grades.

Conclusions: Reliable anterior operation can produce good results for cervical fracture and dislocation with unilateral vertebral artery injury. Detecting the course of uninjured vertebral artery before operation and locating the anatomical site during operation are effective to avoid damaging vertebral artery of uninjured side.

Download full-text PDF

Source

Publication Analysis

Top Keywords

vertebral artery
32
unilateral vertebral
16
fracture dislocation
12
artery injury
12
vertebral
9
operative treatment
8
treatment cervical
8
cervical fracture
8
artery
8
cervical spine
8

Similar Publications

Paradoxical embolism occurs when a clot originates in the venous system and traverses through a pulmonary or intracardiac shunt into the systemic circulation, with a mortality rate of around 18%. The risk factors for arterial embolism and venous thrombosis are similar, but different disease entities can lead to a hypercoagulable state of the blood, including antithrombin III (AT III) deficiency. We report the case of a 43-year-old man with a massive central pulmonary embolism with a rider embolus and concomitant aortic arch embolism with involvement of the brachiocephalic trunk, bilateral subclavian and axillary arteries, and the right vertebral artery, followed by a secondary ischaemic stroke.

View Article and Find Full Text PDF

Acute vertigo or dizziness is a frequent presentation to the emergency department (ED), making up between 2.1% and 4.4% of all consultations.

View Article and Find Full Text PDF

Percutaneous vertebroplasty (PVP) is a widely utilized minimally invasive technique originally developed for the treatment of vertebral compression fractures. It has since expanded to treat osteoporotic vertebral compression fractures, pathologic vertebral fractures resulting from primary or secondary spinal tumors, and traumatic spinal fractures. Despite its benefits, PVP is associated with significant complications, the most common of which is bone cement leakage.

View Article and Find Full Text PDF

Proximal protection devices for carotid artery stenting - A benchtop assessment of flow reversal performance.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology (J.L., E.A.B., C.B., J.C., R.K., W.B., D.F.K), and Department of Neurologic Surgery (Y.C.S., R.K., W.B.), Mayo Clinic, Rochester, MN, United States; Department of Stroke Research (J.L.), Vall d'Hebron Research Institute, Barcelona, Spain; From the Global Institute of Future Technology (Y.L.), Shanghai Jiao Tong University, Shanghai, China; Department of Neurointerventional Radiology (J.C.), Bicetre University Hospital, Le Kremlin Bicetre, France.

Background And Purpose: Proximal protection devices, such as TransCarotid Artery Revascularization (TCAR, SilkRoad Medical, Sunnyvale), aim to yield better outcomes in carotid artery stenting (CAS) than distal protection devices by preventing plaque embolization to the brain. However, transfemoral catheters may not fully reverse flow from the external carotid artery (ECA) to the internal carotid artery (ICA). We assess a new balloon-sheath device, Femoral Flow Reversal Access for Carotid Artery Stenting (FFRACAS), for this purpose.

View Article and Find Full Text PDF

A reduction in cerebral blood flow (CBF) has been observed during spaceflight and bed rest. We aimed to examine the magnitude and regional heterogeneity of the decrease in CBF during bed rest compared to posture changes on Earth. Seventeen participants (age, 29 ± 9 years, 7 females) were studied in the upright and supine posture and over 3 days of bed rest.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!