Optimized anisotropic rotational invariant diffusion scheme on cone-beam CT.

Med Image Comput Comput Assist Interv

Signals and System, University of Twente, The Netherlands.

Published: November 2010

Cone-beam computed tomography (CBCT) is an important image modality for dental surgery planning, with high resolution images at a relative low radiation dose. In these scans the mandibular canal is hardly visible, this is a problem for implant surgery planning. We use anisotropic diffusion filtering to remove noise and enhance the mandibular canal in CBCT scans. For the diffusion tensor we use hybrid diffusion with a continuous switch (HDCS), suitable for filtering both tubular as planar image structures. We focus in this paper on the diffusion discretization schemes. The standard scheme shows good isotropic filtering behavior but is not rotational invariant, the diffusion scheme of Weickert is rotational invariant but suffers from checkerboard artifacts. We introduce a new scheme, in which we numerically optimize the image derivatives. This scheme is rotational invariant and shows good isotropic filtering properties on both synthetic as real CBCT data.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-642-15711-0_28DOI Listing

Publication Analysis

Top Keywords

rotational invariant
16
invariant diffusion
8
diffusion scheme
8
surgery planning
8
mandibular canal
8
good isotropic
8
isotropic filtering
8
diffusion
6
scheme
5
optimized anisotropic
4

Similar Publications

An Infrared and Visible Image Alignment Method Based on Gradient Distribution Properties and Scale-Invariant Features in Electric Power Scenes.

J Imaging

January 2025

State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.

In grid intelligent inspection systems, automatic registration of infrared and visible light images in power scenes is a crucial research technology. Since there are obvious differences in key attributes between visible and infrared images, direct alignment is often difficult to achieve the expected results. To overcome the high difficulty of aligning infrared and visible light images, an image alignment method is proposed in this paper.

View Article and Find Full Text PDF

A cultural adaptation study of nursing informatics competency scale.

Nurse Educ Pract

January 2025

Ataturk University, Nursing Faculty, Public Health Nursing Department, Erzurum, Turkey.

Objective: The objective of this study is to examine the factor structure, internal consistency reliability and responsiveness of an instrument related to the informatics competency of nurses.

Background: Informatics is a scientific discipline that needs to be integrated into nursing practice. There is no current and valid tool to measure the informatics competency of nurses in Turkey.

View Article and Find Full Text PDF

SIRE: Scale-invariant, rotation-equivariant estimation of artery orientations using graph neural networks.

Med Image Anal

January 2025

Department of Applied Mathematics, Technical Medical Centre, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands.

The orientation of a blood vessel as visualized in 3D medical images is an important descriptor of its geometry that can be used for centerline extraction and subsequent segmentation, labeling, and visualization. Blood vessels appear at multiple scales and levels of tortuosity, and determining the exact orientation of a vessel is a challenging problem. Recent works have used 3D convolutional neural networks (CNNs) for this purpose, but CNNs are sensitive to variations in vessel size and orientation.

View Article and Find Full Text PDF

Liquid water still remains an ubiquitous liquid whose molecular organization requires careful investigation. In this work, we present a study of the second harmonic scattering (SHS) intensity for two different scattering angles, namely, the forward and the right angle geometries. This method performed at optical wavelengths is indeed selective toward long correlation lengths.

View Article and Find Full Text PDF

We present the theory and implementation of a fully variational wave function-density functional theory (DFT) hybrid model, which is applicable to many cases of strong correlation. We denote this model as the multiconfigurational self-consistent on-top pair-density functional theory (MC-srPDFT) model. We have previously shown how the multiconfigurational short-range DFT (MC-srDFT) hybrid model can describe many multiconfigurational cases of any spin symmetry and also state-specific calculations on excited states [Hedegård et al.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!