Transcatheter aortic valve implantation is an emerging technique to be applied in patients with aortic valve defects. Angiographic and fluoroscopic X-ray imaging with a C-arm system is crucial in these minimally invasive procedures. We describe a prototypical system based on the ability to acquire a 3D C-arm CT image during transcatheter aortic valve implantations. It supports the physician in measuring critical anatomical parameters, finding an optimum C-arm angulation, and guiding the positioning and deployment of the prosthesis by 3D overlay with fluoroscopic images. To yield high acceptance by the physicians in the operating room, our approach is fast, fully integrated into an angiographic C-arm system, and designed to minimize the necessary user interaction. We evaluate the accuracy of our system on 20 clinical cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/978-3-642-15705-9_46 | DOI Listing |
JACC Adv
December 2024
Department of Interventional Cardiology& structural heart interventions, NICVD, Karachi, Pakistan.
Background: Patients with complex valvular heart disease (VHD) should be evaluated by a multidisciplinary heart team (HT). In low- and middle-income countries, referral practices are more variable, permitting any physician to refer patients directly to a cardiac surgeon without prior formal evaluation by a cardiologist with expertise in VHD.
Objectives: The goal of the study was to examine the demographics of VHD patients seen in a large heart valve center in a low- and middle-income country and to assess the impact of the multidisciplinary HT in patients referred for valve surgery.
JACC Adv
December 2024
Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Int J Cardiol Cardiovasc Risk Prev
March 2025
Department of Internal Medicine, University of New Mexico Health Sciences Center, Albuquerque, NM, USA.
Background: Transcatheter aortic valve replacement (TAVR) has significantly advanced the treatment of severe aortic stenosis (AS), particularly in elderly patients who often have coexisting coronary artery disease (CAD). Chronic total occlusion (CTO), a severe form of CAD, may negatively impact outcomes in TAVR patients, though data are limited. This meta-analysis aims to evaluate the impact of CTO on TAVR outcomes.
View Article and Find Full Text PDFJ Arrhythm
February 2025
Division of Cardiology, Department of Medicine, Heart Rhythm Center Taipei Veterans General Hospital Taipei Taiwan.
With the cases of mechanical valves, especially double mitral and aortic valves, ablation at the left ventricle is very challenging. This case report used equipments that are readily available in the Electrophysiology laboratory, which can make the access feasible.
View Article and Find Full Text PDFHeliyon
January 2025
Lithuanian University of Health Sciences, Faculty of Medicine, A.Mickeviciaus street, 9, LT-44307, Kaunas, Lithuania.
Introduction: is a formidable pathogen that poses a significant threat to immunocompromised and might cause rare atypical forms of the disease especially complicated with coinfection.
Case: We present a case of a patient with meningoencephalitis, endocarditis, sepsis, and osteomyelitis, highlighting the complexities of managing disseminated polymicrobial infection. A 64-year-old female with multiple myeloma treated with chemotherapy presented with fever, altered mental status, nausea, and diarrhea to the emergency department.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!