In the present work, the oxidative electrochemistry of nitrite on the poly(3,4-ethylenedioxythiophene)/iron phthalocyanine/multi-wall carbon nanotubes-(PEDOT/FePc/MWCNT) modified screen-printed carbon electrodes (SPCE) has been investigated. The parameters, such as overpotential, current density and rate constant at PEDOT/FePc/MWCNT-modified SPCE, were compared with an un-modified, FePc-, and FePc/MWCNT-modified SPCE for electro-oxidation of nitrite. As compared with the un-modified SPCE, an increase in the anodic peak current density (J(pa)) (∼100%) along with a decrease in the anodic peak potential (E(pa)) of ∼150mV for electro-oxidation of nitrite at the FePc-modified SPCE was observed. When an under-layer of MWCNT was introduced onto FePc-modified SPCE, denoted as FePc/MWCNT-modified SPCE, and the number of FePc/MWCNT bilayer was optimized, the heterogeneous electron transfer rate constant (k) at FePc/MWCNT-modified SPCE was enhanced about 7.8 times as compared with that at FePc-modified SPCE. Moreover, as a layer of PEDOT film was electrodeposited onto the FePc/MWCNT-modified SPCE, denoted as PEDOT/FePc/MWCNT-modified SPCE, a significant increase in current response along with a remarkable decrease in E(pa) were noticed. This can be attributed to the pre-concentration effect induced by the electrostatic interaction between the negatively charged nitrite and oxidized PEDOT film. On the whole, the PEDOT/FePc/MWCNT-modified SPCE greatly reduces the overpotential of ∼330mV along with 3.5 times enhanced the peak current density for the electro-oxidation of nitrite as compared with un-modified SPCE. The sensitivity and limit of detection (S/N=3) for the PEDOT/FePc/MWCNT-modified SPCE were found to be as 638mAcm(-2)M(-1) and 71nM, respectively. Notably, PEDOT/FePc/MWCNT-modified SPCE has a lower sensing potential than compared to several other modified electrodes. The developed sensor was also applied for the determination of nitrite in tap water sample.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2010.08.010DOI Listing

Publication Analysis

Top Keywords

pedot/fepc/mwcnt-modified spce
20
fepc/mwcnt-modified spce
16
spce
15
current density
12
compared un-modified
12
electro-oxidation nitrite
12
fepc-modified spce
12
poly34-ethylenedioxythiophene/iron phthalocyanine/multi-wall
8
phthalocyanine/multi-wall carbon
8
rate constant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!