Our aim in this study was to determine an optimal delay time of hepatic arterial phase (HAP) imaging of hypervascular hepatocellular carcinomas (HCCs) in dynamic contrast-enhanced MDCT (DCE-CT) by use of the bolus-tracking method. The time-enhancement curves (TECs) of the aorta and the contrast of the hepatic arterial and portal system (APC) in the pharmacokinetic analysis were calculated. The clinical study included 41 patients with known or suspected HCC who underwent DCE-CT. The TECs of the aorta and the tumor-liver contrast (TLC) in the clinical study were calculated. On pharmacokinetic analysis, the peak aortic enhancement and the peak APC simulated under conditions of an injection duration of 30 s and an iodine load of 500 mg I/kg body weight were observed 18.5 and 22.5 s, respectively, after the trigger threshold (increased CT value 100 Hounsfield units), respectively. In the clinical study, the peak aortic enhancement and the peak TLC were observed 17.2 and 24.8 s after the trigger threshold, respectively. The optimal delay times until peak aortic enhancement and peak HAP were 15-17 and 19-21 s after the trigger threshold, respectively, under the following conditions: injection dose, 500 mg I/kg body weight; injection duration, 30 s; acquisition time, 5 s; and the trigger threshold. In addition, the peak TLC was achieved 4-7 s after the time to peak aortic enhancement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-010-0105-yDOI Listing

Publication Analysis

Top Keywords

peak aortic
16
aortic enhancement
16
trigger threshold
16
hepatic arterial
12
pharmacokinetic analysis
12
clinical study
12
enhancement peak
12
arterial phase
8
optimal delay
8
tecs aorta
8

Similar Publications

Impact of measurement location on direct mitral regurgitation quantification using 4D flow CMR.

J Cardiovasc Magn Reson

January 2025

Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA. Electronic address:

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) shows promise for quantifying mitral regurgitation (MR) by allowing for direct regurgitant volume (RVol) measurement using a plane precisely placed at the MR jet. However, the ideal location of a measurement plane remains unclear. This study aims to systematically examine how varying measurement locations affect RVol quantification and determine the optimal location using the momentum conservation principle of a free jet.

View Article and Find Full Text PDF

This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.

View Article and Find Full Text PDF

Background: Patients with low-flow, low-gradient (LFLG) aortic stenosis (AS) have precarious hemodynamics and are a fragile population for intervention. Quantification of aortic valve calcification (AVC) severity is a critical component of the evaluation for transcatheter aortic valve replacement (TAVR); this study aims to further clarify its utility for risk stratification in LFLG AS.

Methods: This retrospective study evaluated 467 patients with LFLG AS undergoing TAVR at a large quaternary-care hospital from January 2019 to December 2021.

View Article and Find Full Text PDF

Online survey about the current status of CT protocols in hepatocellular carcinoma (HCC) in the year 2023/2024. Moreover, the usage of structured reporting using LI-RADS and mRECIST was surveyed and the results were compared with a survey from 2020.Radiologists working in outpatient or inpatient care in Germany were invited.

View Article and Find Full Text PDF

Aims: The Tpeak-Tend interval on electrocardiogram may be a predictor of worse outcomes in Takotsubo syndrome (TTS), but the mechanisms have not been fully determined. This study aimed to investigate the relationships between the corrected Tpeak-Tend (cTp-e) interval and coronary microvascular-dysfunction (CMD) assessed by the angiography-derived index of microvascular resistance (Angio-IMR) and the in-hospital prognosis in patients with TTS.

Methods And Results: We retrospectively evaluated 111 consecutive patients admitted for TTS who underwent coronary angiography at Kindai University Hospital from October 2009 to July 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!