Background: Humidification by artificial means must be provided when the upper airway is bypassed during mechanical ventilation. Heated humidification (HH) and heat and moisture exchangers (HMEs) are the most commonly used types of artificial humidification in this situation.

Objectives: To determine whether HHs or HMES are more effective in preventing mortality and other complications in people who are mechanically ventilated.

Search Strategy: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2010, Issue 4) and MEDLINE, EMBASE and CINAHL (January, 2010) to identify relevant randomized controlled trials.

Selection Criteria: We included randomized controlled trials comparing HMEs to HHs in mechanically ventilated adults and children. We included randomized crossover studies.

Data Collection And Analysis: We assessed the quality of each study and extracted the relevant data. Where appropriate, results from relevant studies were meta-analyzed for individual outcomes.

Main Results: We included 33 trials with 2833 participants; 25 studies were parallel group design (n = 2710) and 8 crossover design (n = 123). Only 3 included studies reported data for infants or children. There was no overall effect on artificial airway occlusion, mortality, pneumonia, or respiratory complications; however, the PaCO(2) and minute ventilation were increased when HMEs were compared to HHs and body temperature was lower. The cost of HMEs was lower in all studies that reported this outcome. There was some evidence that hydrophobic HMEs may reduce the risk of pneumonia and that blockages of artificial airways may be increased with the use of HMEs in certain subgroups of patients.

Authors' Conclusions: There is little evidence of an overall difference between HMEs and HHs. However, hydrophobic HMEs may reduce the risk of pneumonia and the use of an HMEs may increase artificial airway occlusion in certain subgroups of patients. Therefore, HMEs may not be suitable for patients with limited respiratory reserve or prone to airway blockage. Further research is needed relating to hydrophobic versus hygroscopic HMEs and the use of HMEs in the pediatric and neonatal populations. As the design of HMEs evolves, evaluation of new generation HMEs will also need to be undertaken.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0b013e3181efb538DOI Listing

Publication Analysis

Top Keywords

hmes
15
heated humidification
8
heat moisture
8
moisture exchangers
8
ventilated adults
8
adults children
8
controlled trials
8
randomized controlled
8
included randomized
8
hmes hhs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!