Channel coupling is a phenomenon that has been investigated for many scattering processes, and is responsible for the formation of cusps or steps in the cross sections for open scattering channels at, or near, the onset of a new scattering channel. It has long been speculated that the opening of the positronium formation channel may lead to the formation of such cusp features in the elastic positron scattering cross section. In this work, elastic scattering of positrons has been measured in the region of the positronium formation threshold for the noble gases He-Xe. Cusplike behavior is observed and, while the features which are observed appear broad, they represent a magnitude of between 4 and 15% of the total elastic cross section. No evidence is found of any other features in this region, at least within the uncertainty of the present data, discounting the possibility of scattering resonances.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.105.073201 | DOI Listing |
Using the first principle calculations, we propose a boron and nitrogen cluster incorporated graphene system for efficient valley polarization. The broken spatial inversion symmetry results in high Berry curvature at and valleys of the hexagonal Brillouin zone in this semiconducting system. The consideration of excitonic quasiparticles within the approximation along with their scattering processes using the many-body Bethe-Salpeter equation gives rise to an optical gap of 1.
View Article and Find Full Text PDFSci Rep
January 2025
Accelerator Operations and Technology Division, Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM, 87545, USA.
The pursuit to operate photocathodes at high accelerating gradients to increase brightness of electron beams is gaining interests within the accelerator community, particularly for applications such as free electron lasers (FEL) and compact accelerators. Cesium telluride (CsTe) is a widely used photocathode material and it is presumed to offer resilience to higher gradients because of its wider band gap compared to other semiconductors. Despite its advantages, crucial material properties of CsTe remain largely unknown both in theory and experiments.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Nuclear Medicine, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
Background: Although F-prostate-specific membrane antigen-1007 (F-PSMA-1007) positron emission tomography/computed tomography (PET/CT) and multiparametric magnetic resonance imaging (mpMRI) are good predictors of prostate cancer (PCa) prognosis, their combined ability to predict prostate-specific antigen (PSA) persistence has not been thoroughly evaluated. In this study, we assessed whether clinical, mpMRI, and F-PSMA-1007 PET/CT characteristics could predict PSA persistence in patients with PCa treated with radical prostatectomy (RP).
Methods: This retrospective study involved consecutive patients diagnosed with PCa who underwent both preoperative mpMRI and PSMA PET/CT scans between April 2019 and June 2022.
Small
January 2025
State Key Laboratory of Crystal Materials, Shandong University, 27th South Shanda Road, Jinan, 250100, China.
The demand for medical imaging with reduced patient dosage and higher resolution is growing, driving the need for advanced X-ray detection technologies. This paper proposes a design paradigm for X-ray detection semiconductors by coupling constituent motifs through crystal structure engineering. The study introduces a strongly anisotropic Aurivillius-type quasi-2D perovskite structure, combining [BiO] groups with stereochemically active lone pair electrons (SCALPEs) and [W/MoO] anionic groups, enabling enhanced X-ray Compton scattering and self-powered capabilities through local electric field ordering.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Physics of Molecular Imaging Systems, RWTH Aachen University, Forckenbeckstraße 55, Aachen, NRW, 52074, GERMANY.
Integrating time-of-flight (ToF) measurements in radiography and computed tomography (CT) enables an approach for scatter rejection in imaging systems that eliminates the need for anti-scatter grids, potentially increasing system sensitivity and image quality. However, present hardware dedicated to the time-correlated measurement of X-rays is limited to a small scale and low density. A switch to highly integrated electronics and detectors is needed to progress towards a medium-scale system capable of acquiring images, while offering a timing resolution below 300 ps FWHM to achieve scatter rejection comparable to current grids.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!