The aim of this study was to measure marginal fit at cylinder-abutment interface, before and after overcasting procedure. A hexagonal implant was fixed to a stainless steel base and a Estheticone-like abutment used during all the experiment. Before casting procedure, gold (Group I) and Ni-Cr-Be (Group II) premachined cylinders were tightened to the abutment with gold and titanium screws (in both groups), with 10Ncm and 20Ncm torque values for the same screw type. Vertical measures were taken at the light microscope (Mitutoyo 5050, Tokyo, Japan) three times in six different parts along the abutment-cylinder interface for each torque value. Cylinders were overcast with Ag-Pd (Group I) or Ni-Cr-Be (Group II) alloy. After casting, the same measures and torque values were repeated. Intragroup differences (10 or 20Ncm torque values, before and after casting) and intergroup differences (10 and 20Ncm torque values, before or after casting) were analyzed by the Paired t Test; (p<0.05). Intragroup differences were observed for G-I (gold, 20Ncm, titanium screw, p=0.044) and for G-II (Ni-Cr-Be, 10Ncm, gold screw, p=0.002). Intergroup differences only were not observed in the G-II group (Ni-Cr-Be, 10 and 20Ncm, titanium screw, p=0.534). Within the limits of this study, the following conclusions can be drawn: 1) Regardless of screw type, marginal misfit was higher for Ni-Cr-Be cylinders after casting, but within acceptable levels of fit; 2) The combination of gold cylinders with gold or titanium screws was the most effective to reduce marginal misfit; 3) Both screw types did not improve marginal fit of Ni-Cr-Be cylinders after overcastting, and 4) Although a 20Ncm torque improved marginal fit in all situations, its use is not recommended due to the increased risk of prosthesis failure. Ni-Cr-Be alloys may be successfully used in single-tooth implant restorations, with no damage to the fit between abutment and prosthetic cylinder.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s1678-77572005000400010 | DOI Listing |
Ultrasound Med Biol
January 2025
School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:
Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.
Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.
Sports (Basel)
January 2025
DMeM, University of Montpellier, INRAE, 34000 Montpellier, France.
Background: Objective training load (TL) indexes used in resistance training lack physiological significance. This study was aimed to provide a muscle physiology-based approach for quantifying TL in resistance exercises (REs).
Methods: Following individual torque-velocity profiling, fifteen participants (11 healthy males, stature: 178.
Bioengineering (Basel)
January 2025
Department of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy.
This study aimed to evaluate the biomechanical performance of two truncated cone implant designs in maxillary sinus lift (MSL) procedures using polyurethane laminas. A total of 128 implants were used. Polyurethane laminas were divided into two groups based on thickness (1 and 3 mm) and two subgroups based on density (20 and 30 pounds per cubic foot, PCF).
View Article and Find Full Text PDFFront Physiol
January 2025
Department of Orthopaedics, Sports Medical Research Group, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Competitive alpine skiing requires a high level of physical fitness to perform sport-specific manoeuvres and to minimise the risk of injury. The aim of this study was to establish reference values for the maximal anatomical cross-sectional area (ACSA) of the individual hamstrings (HAM) and quadriceps (QUAD) muscles as well as for the maximal voluntary torque (MVT) during knee flexion (KF) and knee extension (KE) of female and male elite competitive alpine skiers. Ultrasound and dynamometer data were obtained from a largely overlapping but not identical dataset.
View Article and Find Full Text PDFKorean J Orthod
January 2025
Private Practice, Ankara, Türkiye.
Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis.
Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm-thick aligners and horizontal attachments, were integrated into the software.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!