Objectives: Concerns have been raised about possible health effects from radiofrequency fields pulsing at around 16 Hz. A radio system used by UK police (TETRA) employs signals which pulse at 17.6 Hz. We tested whether exposure to a continuous wave signal at 385.25 MHz or a TETRA-like signal resulted in symptoms among users reporting sensitivity to TETRA compared to users not reporting sensitivity to TETRA.

Methods: 60 sensitive and 60 non-sensitive users were exposed to three 50 min conditions: a signal with a 16 Hz component, a continuous wave condition and a sham condition. The mean radiated power for the 16 Hz and continuous wave conditions was 250 mW. The order of conditions was randomised and testing was conducted double-blind. Participants reported the severity of eight symptoms during and after each exposure, their mood state at the end of each exposure, and whether they could tell which sessions involved active signals. The study was registered in advance with the ISRCTN register.

Results: Exposure to the continuous wave signal increased ratings of headache in all participants, fatigue in non-sensitive participants and difficulty concentrating in sensitive participants. Paradoxically, it reduced sensations of itching in sensitive participants. These effects were not observed in the condition with 16 Hz pulsing, except for those relating to concentration. Adjusting for multiple comparisons removed most significant effects, but not those relating to itch.

Conclusions: The results suggested that exposure to TETRA signals is not responsible for symptoms reported by some users, although exposure to a continuous wave signal may affect symptoms. Clinical trial number ISRCTN 73321766.

Download full-text PDF

Source
http://dx.doi.org/10.1136/oem.2010.055889DOI Listing

Publication Analysis

Top Keywords

continuous wave
20
exposure continuous
12
wave signal
12
tetra-like signal
8
users reporting
8
reporting sensitivity
8
sensitive participants
8
exposure
7
signal
6
continuous
5

Similar Publications

Traveling waves of excitation arise from the spatial coupling of local nonlinear events by transport processes. In corrosion systems, these electro-dissolution waves relay local perturbations across large portions of the metal surface, significantly amplifying overall damage. For the example of the magnesium alloy AZ31B exposed to sodium chloride solution, we report experimental results suggesting the existence of a vulnerable zone in the wake of corrosion waves where local perturbations can induce a unidirectional wave pulse or segment.

View Article and Find Full Text PDF

Background: Altered neuronal timing and synchrony are biomarkers for Alzheimer's disease (AD) and correlate with memory impairments. Electrical stimulation of the fornix, the main fibre bundle connecting the hippocampus to the septum, has emerged as a potential intervention to restore network synchrony and memory performance in human AD and mouse models. However, electrical stimulation is non-specific and may partially explain why fornix stimulation in AD patients has yielded mixed results.

View Article and Find Full Text PDF

Objective:  This study compares the color change of non-vital anterior teeth after laser-activated bleaching and conventional walking bleaching technique.

Materials And Methods:  Sixty extracted teeth were endodontically treated, stained in a black tea solution, and the baseline shade was measured using a spectrophotometer (Easyshade, VITA). Bleaching was done using either: internal bleaching with 35% HO (Opalescence Endo) and then tooth sealed for 5 days (Gr1), 35% HO (JW Next) for 7 minutes (Gr2), internal and external bleaching for 7 minutes (Gr3), diode laser-activated internal bleaching for 30 seconds (940 nm, continuous wave, 2 W, noncontact mode, 300 um, non-initiated tip), wait for 7 minutes, second laser application for 30 seconds, tooth sealed for 5 days (Gr4), diode laser-activated internal bleaching for 24 hours (Gr5), or diode laser-activated internal and external bleaching for 24 hours (Gr6) ( = 10).

View Article and Find Full Text PDF

High-performance triboelectric nanogenerator employing a swing-induced counter-rotating motion mechanism and a dual potential energy storage and release strategy for wave energy harvesting.

Mater Horiz

January 2025

School of Materials Science and Engineering, Energy Materials and Devices Key Lab of Anhui Province for Photoelectric Conversion, Anhui University, Hefei, Anhui 230601, China.

The triboelectric nanogenerator (TENG) has been proved to be a very promising marine energy harvesting technology. Herein, we have developed a high-performance triboelectric nanogenerator (SD-TENG) with low friction, high durability, swing-induced counter-rotating motion mechanism (SICRMM) and dual potential energy storage and release strategy (DPESRS). The unique counter-rotating motion mechanism enabled SD-TENG to convert the external linear and swing motion energy into rotation motion energy of the inner and outer cylinders, and then converted it into a controllable power output.

View Article and Find Full Text PDF

The ultimate limit for laser miniaturization would be achieving lasing action in the lowest-order cavity mode within a device volume of ≤(λ/2n), where λ is the free-space wavelength and n is the refractive index. Here we highlight the equivalence of localized surface plasmons and surface plasmon polaritons within resonant systems, introducing nanolasers that oscillate in the lowest-order localized surface plasmon or, equivalently, half-cycle surface plasmon polariton. These diffraction-limited single-mode emitters, ranging in size from 170 to 280 nm, harness strong coupling between gold and InGaAsP in the near-infrared (λ = 1,000-1,460 nm), away from the surface plasmon frequency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!