In addition to lowering cholesterol, 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors, or statins, have been shown to modulate gene expression in endothelial cells. The effect of statins on cell adhesion molecule expression is unclear and largely unexplored in endothelial cells exposed to shear stress, an important regulator of endothelial cell function. In this study, the effect of simvastatin on vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1) expression was evaluated in human abdominal aortic endothelial cells (HAAEC) conditioned with various levels of laminar wall shear stress with or without tumor necrosis factor alpha (TNFα). As expected, TNFα alone greatly enhanced both VCAM-1 and ICAM-1 mRNA and protein. In static culture, simvastatin potentiated the TNFα-induced increase in VCAM-1 and ICAM-1 mRNA but not total protein at 24 h. Mevalonate, a precursor to cholesterol biosynthesis, eliminated the effect of simvastatin. Exposure of endothelial cells to elevated levels of laminar shear stress during simvastatin treatment prevented the potentiating effect of simvastatin on cell adhesion molecule mRNA. A shear stress of 12.5 dyn/cm² eliminated the increase in VCAM-1 by simvastatin, while 25 dyn/cm² was needed for ICAM-1. We conclude that simvastatin enhances VCAM-1 and ICAM-1 gene expression in TNFα-activated endothelial cells through inhibition of HMG-CoA reductase. High levels of laminar shear stress prevented the upregulation of VCAM-1 and ICAM-1 by simvastatin suggesting that an induction of cell adhesion molecules by statins may not occur in endothelial cells exposed to shear stress from blood flow.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejphar.2010.09.016DOI Listing

Publication Analysis

Top Keywords

shear stress
28
endothelial cells
28
cell adhesion
16
vcam-1 icam-1
16
laminar shear
12
adhesion molecule
12
levels laminar
12
molecule expression
8
endothelial
8
hmg-coa reductase
8

Similar Publications

Introduction: In-stent restenosis remains a significant challenge in coronary artery interventions. This study aims to explore the relationship between exercise intensity and stent design, focusing on the coupled response of the stent structure and hemodynamics at different exercise intensities.

Methods: A coupled balloon-stent-plaque-artery model and a fluid domain model reflecting structural deformation were developed to investigate the interaction between coronary stents and stenotic vessels, as well as their impact on hemodynamics.

View Article and Find Full Text PDF

High-fidelity computational fluid dynamics modeling to simulate perfusion through a bone-mimicking scaffold.

Comput Biol Med

December 2024

University of Colorado Boulder, Paul M. Rady Department of Mechanical Engineering, Boulder, CO, USA; Biofrontiers Institute, University of Colorado, Boulder, CO, 80309, USA. Electronic address:

Breast cancer cells sense shear stresses in response to interstitial fluid flow in bone and induce specific biological responses. Computational fluid dynamics models have been instrumental in estimating these shear stresses to relate the cell mechanoresponse to exact mechanical signals, better informing experiment design. Most computational models greatly simplify the experimental and cell mechanical environments for ease of computation, but these simplifications may overlook complex cell-substrate mechanical interactions that significantly change shear stresses experienced by cells.

View Article and Find Full Text PDF

The influence of solute concentration and filtration on mesoscale clusters of flufenamic acid, a typical pharmaceutical compound, in ethanol.

J Colloid Interface Sci

December 2024

Department of Chemical Sciences, SSPC, the Research Ireland Centre for Pharmaceuticals, Bernal Institute, University of Limerick, V94 T9PX, Ireland. Electronic address:

Hypothesis: It is hypothesised in this work that mesoscale clusters will be present in both undersaturated and supersaturated solutions of organic pharmaceutical molecules. These clusters, being loose aggregates, could be sensitive to shear forces experienced during filtration. Thus, comparing the behaviour of these clusters alongside nanoparticles during filtration-an important sample treatment parameter during crystallization-will elucidate qualitative differences from solid, crystalline nanoparticles of similar size.

View Article and Find Full Text PDF

The varied material and the inherent complex microstructure make predicting the effective stiffness of fused deposition modeling (FDM) printed polylactic acid (PLA)/carbon fiber (CF) composite a troublesome problem. This article proposes a microstructure scanning electron microscope (SEM) mapping modeling and numerical mean procedure to calculate the effective stiffness of FDM printing PLA/CF laminates. The printed PLA/CF parts were modeled as a continuum of 3D uniform linear elasticity with orthotropic anisotropy, and their elastic behavior was characterized by orthotropic constitutive relations.

View Article and Find Full Text PDF

Introduction: Up to one in five will suffer from osteoporotic vertebral fracture within their lifetime. Accurate fracture prediction poses challenges using bone mineral density (BMD) measures. Trabecular bone strains may be influenced by the underlying intervertebral disc (IVD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!