AI Article Synopsis

Article Abstract

The analysis of radiation transfer in specular reflector configurations, with multiple or distorted images of an extended radiation source, appears to be so complicated that the need for detailed ray tracing is usually considered inescapable. I show that the number of calculations can be greatly reduced when the source is isotropic. Starting from the fact that the radiation received from an isotropic source depends only on the emissive power of the source and on the angular contour subtended by the source, I show that only edge rays need to be traced, no matter what the curvature of the reflector. Edge rays are rays that pass through the edge of the source or of the reflector. This approach makes it possible to obtain the exact solution for configurations for which the number of reflections is not impractically high. For the solution of general configurations I propose a fast numerical procedure. Based on interpolation between the impact points of a small number of edge rays, it offers high accuracy and unli ted resolution; the convergence is rapid as the number of rays is increased. A test that uses the example of a generalizedcompound parabolic concentrator demonstrates that with this method one can achieve accuracies that are far better than with conventional ray-trace methods while tracing a number of rays that are orders of magnitude smaller.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.33.001248DOI Listing

Publication Analysis

Top Keywords

edge rays
12
analysis radiation
8
radiation transfer
8
transfer specular
8
number rays
8
source
6
rays
6
number
5
edge-ray method
4
method analysis
4

Similar Publications

The correlation between clinical outcomes and preoperative/postoperative measures of the lateral center-edge angle (LCEA) will help establish the cutoff values for this measurement and determine whether to obtain it from the lateral acetabular rim (LCEAR) or the lateral end of the sourcil (LCEAS). The hypothesis was that the LCEAS would be more sensitive than the LCEAR. An upper cutoff value of LCEA could predict better functional outcomes in FAI patients.

View Article and Find Full Text PDF

Extreme ultraviolet (EUV) lithography is a cutting-edge technology in contemporary semiconductor chip manufacturing. Monitoring the EUV beam profiles is critical to ensuring consistent quality and precision in the manufacturing process. This study uncovers the practical use of fluorescent nanodiamonds (FNDs) coated on optical image sensors for profiling EUV and soft X-ray (SXR) radiation beams.

View Article and Find Full Text PDF

Reducing radiation-induced hypothyroidism by modified delineation of cervical lymphatic drainage area for nasopharyngeal carcinoma treated by intensity-modulated radiation Therapy: 3 years' experience.

Radiother Oncol

January 2025

NHC Key Laboratory of Personalized Diagnosis and Treatment of Nasopharyngeal Carcinoma, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, Nanchang 330029 China; Department of Radiation Oncology, Jiangxi Clinical Research Center for Cancer, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, Nanchang 330029 China. Electronic address:

Background And Purpose: Radiation-induced hypothyroidism (RIHT) is a late complication of intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). We evaluated thyroid protection in NPC patients receiving IMRT using modified delineation (MD) of cervical lymphatic drainage areas, sparing the common carotid artery within the clinical target volume (CTV), to assess its impact on thyroid function and survival outcomes.

Materials And Methods: This retrospective cohort study included patients without metastatic lymph nodes at levels III and IV who received neck irradiation.

View Article and Find Full Text PDF

A Simple One-Pot Method for the Synthesis of BiFeO/BiFeO Heterojunction for High-Performance Photocatalytic Degradation Applications.

Int J Mol Sci

December 2024

Joint International Research Laboratory of Information Display and Visualization, School of Electronic Science and Engineering, Southeast University, Nanjing 210096, China.

This study presents a facile one-pot synthesis method to fabricate BiFeO-BiFeO-BiO heterojunction photocatalysts with controllable compositions and pure phases. Three different binary heterojunctions (BiFeO/BiFeO, BiFeO/BiO, and BiFeO/BiO) and a ternary BiFeO/BiFeO/BiO heterojunction were formed, all exhibiting significantly enhanced photocatalytic performance for the degradation of methylene blue (MB) and phenol under visible light irradiation, outperforming the individual compositions. Notably, the BiFeO/BiFeO heterojunction achieved the highest degradation efficiency (93.

View Article and Find Full Text PDF

Two-dimensional layered double hydroxides (LDHs) are ideal candidates for a large number of (bio)catalytic applications due to their flexible composition and easy to tailor properties. Functionality can be achieved by intercalation of amino acids (as the basic units of peptides and proteins). To gain insight on the functionality, we apply resonant inelastic soft x-ray scattering and near edge x-ray absorption fine structure spectroscopy to CaFe LDH in its pristine form as well as intercalated with the amino acids proline and cysteine to probe the electronic structure and its changes upon intercalation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!