In an industrial hall, with large variations of radon concentration within minutes, simultaneous measurements were done with two types of passive radon detectors and an active radon measuring device. The widely used passive radon detector of the National Radiological Protection Board (NRPB) [Health Protection Agency (former NRPB) (HPA)]/Statens strålskyddsinstitut (Swedish Radiation Protection Institute) (SSI) type produced anomalous results, seemingly uncorrelated to the radon concentration which was in the order of hundreds of becquerels per metre, usually underestimating but occasionally overestimating. We tried to reproduce similar exposure characteristics in our laboratory, but failed to reproduce the anomalous readings. We suspected, but could not prove, that the anomalous results were due to the combination of high radon concentration gradients, with pressure-driven air exchange between the inside of the detector holder and the outside atmosphere. Moreover, this theory was at least partly contradicted when we drilled holes in the detector holder. Although of interest, this effect is not likely to have substantially influenced any radon surveys, given the unusual nature of the exposure that caused the effect.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncq262 | DOI Listing |
Probl Radiac Med Radiobiol
December 2024
State Institution «O.M. Marzіeiev Institute for Public Health of the National Academy of Medical Sciences of Ukraine», 50 Hetman Pavlo Polubotok Str., Kyiv, 02094, Ukraine.
Objective: assessment of probable exposure levels from radon and NORM in workplaces within the context of justi fying radiation protection plans in an existing exposure situation.
Materials And Methods: Materials regarding the assessment of naturally occurring radioactive material (NORM) con tent in tailing from mining and processing industries in Ukraine and assessments of contamination levels of industri al sites of oil and gas enterprises were used for estimating the probable range of effective doses (ED) of workers fromNORM at industrial enterprises. These materials were obtained as a result of research conducted by specialists from theRadiation Protection Laboratory of the State Institution «O.
Biomed Environ Sci
November 2024
Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China.
Objective: We aimed to analyze the current indoor radon level and estimate the population risk of radon-induced lung cancer in urban areas of China.
Methods: Using the passive monitoring method, a new survey on indoor radon concentrations was conducted in 2,875 dwellings across 31 provincial capital cities in Chinese mainland from 2018 to 2023. The attributable risk of lung cancer induced by indoor radon exposure was estimated based on the risk assessment model.
Radiat Prot Dosimetry
November 2024
Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand.
This study aimed to determine the annual effective dose resulting from radon and thoron progeny inhalation. The levels of radon, thoron, and progeny were assessed in residences situated in the Doi Lo region of Chiang Mai, Thailand. Indoor radon and thoron concentrations were detected using passive discriminative detectors.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2024
Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori 036-8564, Japan.
Passive radon monitors with CR-39s are widely used in major epidemiological surveys. However, the conventional CR-39 track density determining strategy makes it difficult to accurately estimate the concentration because of the heterogeneity of tracks on CR-39s. This study introduced a stochastic method, Latin hypercube sampling, to improve the track density determining strategy and provide the probability distribution of 222Rn concentration and equilibrium equivalent thoron concentration.
View Article and Find Full Text PDFJ Environ Radioact
December 2024
Institute of Radiation Emergency Medicine, Hirosaki University, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!