A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ischaemically induced alterations in electrical activity and mechanical performance of isolated blood perfused canine myocardial preparations. | LitMetric

Study Objective: The aim was to investigate the direct effect of ischaemic insult on the electrical activity or mechanical performance of the sinoatrial node, atrioventricular node or Purkinje fibres (ventricular papillary muscle) of the dog heart.

Design: The three isolated tissues independently mounted in a water jacketed glass container were cross circulated through their respective arteries at a constant pressure (120 mm Hg) with arterial blood from a heparinised supporting dog under sodium pentobarbitone anaesthesia. Rate of automatic rhythmical contractions (automaticity) or tension development was measured before, during, and after ischaemia (30 min). EXPERIMENTAL PREPARATIONS: Seven sinoatrial nodes, five atrioventricular nodes, and 11 papillary muscles were prepared from the heart of mongrel dogs, weighing 11.5-15 kg.

Measurements And Main Results: The automaticity of the sinoatrial node and atrioventricular node exhibited a high degree of resistance to ischaemia, whereas both the automaticity (Purkinje fibres) and the tension development of papillary muscle were more susceptible to ischaemia and ultimately disappeared during ischaemia. Upon resumption of the blood supply, contractility rapidly returned to preischaemic levels. However, force-frequency analyses revealed that even after reperfusion, papillary muscle had lost the ability to respond normally to stimulus frequencies greater than 2 Hz.

Conclusions: The findings suggest (1) that in the special excitatory and conductive system, the more distal the segment is to the sinoatrial node, the more vulnerable it is to ischaemia; (2) that the myocardium impaired by ischaemic insult lacks functional reserve, as evidenced by enlargement of the differences between the alternate tensions of pulsus alternans; and (3) that cessation of the blood supply does not predominantly damage those tissues whose functions are mainly regulated by a slow inward calcium current.

Download full-text PDF

Source
http://dx.doi.org/10.1093/cvr/24.10.786DOI Listing

Publication Analysis

Top Keywords

sinoatrial node
12
papillary muscle
12
electrical activity
8
activity mechanical
8
mechanical performance
8
ischaemic insult
8
node atrioventricular
8
atrioventricular node
8
purkinje fibres
8
tension development
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!