Effect of heliox on heart rate kinetics and dynamic hyperinflation during high-intensity exercise in COPD.

Eur J Appl Physiol

Laboratoire de Physio-Pathologie Respiratoire, Equipe de Recherche ER 10, Faculté de Médecine Pierre et Marie Curie (site Pitié-Salpêtrière), Université Paris VI, Paris, France.

Published: February 2011

Respiratory mechanical abnormalities in patients with chronic obstructive pulmonary disease (COPD) may impair cardiodynamic responses and slow down heart rate (HR) kinetics compared with normal resulting in reduced convective oxygen delivery during exercise. We reasoned that heliox breathing (79% helium-21% oxygen) and the attendant reduction of operating lung volumes should accelerate HR kinetics in the transition from rest to high-intensity exercise. Eleven male ambulatory patients with clinically stable COPD undertook constant work-rate cycle testing at 80% of each individuals' maximum work capacity while breathing room air (RA) or heliox (HX), randomly. Mean response time (MRT) for HR and dynamic end-expiratory lung volume (EELV) were measured. Resting EELV was not affected by HX breathing, while exercise EELV decreased significantly by 0.23 L at isotime during HX breathing compared with RA. During HX breathing, MRT for HR significantly accelerated (p = 0.002) by an average of 20 s (i.e., 17%). Speeded MRT for HR correlated with indices of reduced lung hyperinflation, such as EELV at isotime (r = 0.88, p = 0.03), and with improved exercise endurance time (r = -0.64, p = 0.03). The results confirm that HX-induced reduction of dynamic lung hyperinflation is associated with consistent improvement in indices of cardio-circulatory function such as HR kinetics in the rest-to-exercise transition in COPD patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00421-010-1643-zDOI Listing

Publication Analysis

Top Keywords

heart rate
8
rate kinetics
8
high-intensity exercise
8
lung hyperinflation
8
exercise
5
breathing
5
heliox heart
4
kinetics
4
kinetics dynamic
4
dynamic hyperinflation
4

Similar Publications

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Background: Sedentary behaviour (SB) is detrimental to cardiometabolic disease (CMD) risk, which can begin in young adulthood. To devise effective SB-CMD interventions in young adults, it is important to understand which context-specific SB (CS-SB) are most detrimental for CMD risk, the lifestyle behaviours that cluster with CS-SBs and the socioecological predictors of CS-SB.

Methods And Analysis: This longitudinal observational study will recruit 500 college-aged (18-24 years) individuals.

View Article and Find Full Text PDF

High-sensitivity cardiac troponin T and N-terminal b-type natriuretic propeptide are associated with cardiac and all-cause mortality in older adults - A population-based ten-year follow-up study.

Clin Chim Acta

December 2024

Southwest Finland Wellbeing Services County, Turku University Hospital Services, Geriatric Medicine, 20521 Turku, Finland; Faculty of Medicine, Department of Clinical Medicine, Unit of Geriatric Medicine, University of Turku and Turku University Hospital, 20700 Turku, Finland.

Background: Cardiac troponin T (cTnT) and N-terminal B-type natriuretic propeptide (proBNP) are mainly used as biomarkers to diagnose specific conditions of the heart, but they also have predictive ability. Our aim was to study their associations with cardiovascular and all-cause mortality in an older population in non-acute conditions.

Methods: A population-based study with a ten-year follow-up.

View Article and Find Full Text PDF

Although angiotensin 1-7 (Ang 1-7) and its role as a part of the "protective" axis of the renin-angiotensin system are well described in the literature, the mechanisms of its angiotensin II-like pressor and tachycardic effects following its acute central administration are not fully understood. It was the aim of the present study to examine which receptors contribute to the aforementioned cardiovascular effects. Ang 1-7 and antagonists for glutamate, GABA, vasopressin, thromboxane A (TP), α-adrenergic, and P2X purinoceptors or modulators of oxidative stress were injected into the paraventricular nucleus of the hypothalamus (PVN) of urethane-anesthetized male Wistar rats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!